The WATCHMAN Left Atrial Appendage Closure Device for Atrial Fibrillation
Published on: February 28, 2012
Real-world experience utilizing the nuvision 4D intracardiac echocardiography catheter for left atrial appendage
Alex Adams1, Riaz Mahmood2, Nivedha Balaji2
1Graduate Medical Education, Cardiovascular Disease Fellowship, Northeast Georgia Medical Center, 743 Spring Street NE, Suite 710, 30501, Gainesville, GA, Georgia. alex.adams2@nghs.com.
Abstract:
Transesophageal echocardiography (TEE) has been the preferred imaging modality to help guide left atrial appendage closure. Newer technologies such as the Nuvision 4D Intracardiac echocardiography (ICE) catheter allow for real-time 3D imaging of cardiac anatomy. There are no direct comparison studies for procedural imaging between TEE and 4D ICE. To evaluate the performance and safety of left atrial appendage (LAA) closure procedures with the Watchman FLX and Amulet, guided by the Nuvision 4D ICE Catheter. This retrospective observational analysis was conducted on institutional LAAO National Cardiovascular Data Registry from January 2022 to March 2023. Patients had undergone LAA closure procedures with the Watchman FLX or Amulet device guided by TEE or a 4D ICE Catheter. The primary outcome evaluated was successful LAAO device placement. A total of 121 patients underwent LAAO device placement with 46 (38.0%) patients guided by 4D ICE during LAAO implantation. The 4D ICE group had a shorter procedural time compared with TEE guidance. Post procedural 45-day TEE post implant was also comparable for both groups with no patients in either group having incomplete closure of the left atrial appendage and peri-device leak > 5 mm. No device related complications (device related access, stroke, or pericardial effusion) occurred in either group at follow-up. There was no significant difference in device implant success or post procedural outcomes at 45 days in either the TEE or 4D ICE group. However, there was a noticeable improvement in procedural time with the 4D ICE catheter.
Related Concept Videos
Heart Valves
The AV valves prevent the backflow of blood from the ventricles to the atria during ventricular contraction. These valves function with the assistance of the chordae tendineae and papillary muscles. When the ventricles are relaxed, the chordae tendineae are slack, allowing blood to flow from the atria into the...
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V) valves at the...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System IV: CMRI
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization