Related Experiment Video
Updated: Jun 25, 2025

Carotid Artery Infusions for Pharmacokinetic and Pharmacodynamic Analysis of Taxanes in Mice
Published on: October 27, 2014
The phenomenon of drug-coating embolism during lower extremity endovascular interventions with paclitaxel-coated
Olesia S Osipova1, Alexander A Gostev1, Andrey A Karpenko1
1Center for Vascular and Hybrid Surgery, Meshalkin National Medical Research Center, Novosibirsk, Russian Federation.
Abstract:
IntroductionThere is a risk of distal embolization lower extremity endovascular interventions. Possibly a drug-coating embolism caused by coating detachment from intravascular devices.MethodsThis review focuses on providing updated information on distal embolism in endovascular revascularization of lower extremity arteries, including the use of drug-coated balloons.ResultsDrug-coating embolism is a special case of distal embolization during recanalization of the arteries of the lower extremities. Preclinical studies have demonstrated embolization of drug-coated balloons during angioplasty of lower extremity arteries. However, the clinical role of drug-coating embolism is not completely clear. A 2020 meta-analysis found an increased risk of major lower extremity amputation after drug-coated balloon angioplasty in patients with critical limb ischemia. But long-term research is emerging to support the safety of using these devices. Perhaps a more thorough assessment of the quality of life and the degree of compensation of lower limb ischemia with an intraoperative assessment of the frequency of peripheral embolizations using ultrasound emboli detection, as well as microcirculation with transcutaneous oximetry and laser Doppler flowmetry of the operated lower limb will allow a more detailed study of the phenomenon of drug-coating embolism and its impact on long-term clinical outcomes.ConclusionAccording to the results of preclinical studies, the use of paclitaxel-coated balloons leads to an increase in the concentration of paclitaxel in distal skeletal muscles. However, paclitaxel concentration in skeletal muscle was significantly higher in first-generation DCBs. The non-target effects of drug-coating balloon are not fully understood and require further study. Understanding the phenomenon of drug-coating embolism can help physicians to better assess the patient risk and to minimize complications.
More Related Videos
05:52Myocardial Infarction by Percutaneous Embolization Coil Deployment in a Swine Model
Published on: November 4, 2021
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Drugs that Stabilize Microtubules
Antiplatelet Drugs: Prostaglandin Synthesis, P2Y12 and Glycoprotein IIb/IIIa Inhibitors
Prostaglandin synthesis inhibitors, exemplified by the widely known aspirin, wield their power by irreversibly acetylating...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
Local Anesthetics: Clinical Application as Intravenous Regional Anesthesia
One of the advantages of...