Assessing the Accuracy of Fitness Smartwatch Data for Cardiovascular and Physical Activity Monitoring: A Validation Study in Digital Health
Published on: February 21, 2025
Data-Fusion-Based Quality Enhancement for HR Measurements Collected by Wearable Sensors
Shenghao Xia1,2, Shu-Fen Wung3, Chang-Chun Chen4
1Statistics GIDP, Department of Mathematics, University of Arizona, Tucson, AZ 85721, USA.
Abstract:
The advancements of Internet of Things (IoT) technologies have enabled the implementation of smart and wearable sensors, which can be employed to provide older adults with affordable and accessible continuous biophysiological status monitoring. The quality of such monitoring data, however, is unsatisfactory due to excessive noise induced by various disturbances, such as motion artifacts. Existing methods take advantage of summary statistics, such as mean or median values, for denoising, without taking into account the biophysiological patterns embedded in data. In this research, a functional data analysis modeling method was proposed to enhance the data quality by learning individual subjects' diurnal heart rate (HR) patterns from historical data, which were further improved by fusing newly collected data. This proposed data-fusion approach was developed based on a Bayesian inference framework. Its effectiveness was demonstrated in an HR analysis from a prospective study involving older adults residing in assisted living or home settings. The results indicate that it is imperative to conduct personalized healthcare by estimating individualized HR patterns. Furthermore, the proposed calibration method provides a more accurate (smaller mean errors) and more precise (smaller error standard deviations) HR estimation than raw HR and conventional methods, such as the mean.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...