Related Experiment Video
Updated: Jun 25, 2025

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Development and Validation of the High-Voltage Direct-Current Modular Multilevel Converter (HVDC-MMC) Model for
Krzysztof Solak1, Waldemar Rebizant1, Frank Mieske2
1Faculty of Electrical Engineering, Wroclaw University of Science and Technology, 50-370 Wrocław, Poland.
Abstract:
The electrical protection of power networks with fault contribution from inverter-based power sources imposes new application challenges that have to be dealt with by protection engineers. This paper describes the development of a study case model of an HVDC-MMC link for testing the protection behaviour of connected converter transformers. The paper summarises the implementation and validation of the converter control as well as enhancements to provide Fault Ride-Through capability and fast fault current injection as required by the German Technical Connection Rules for HVDC. The grid code standard requires positive- and negative-sequence reactive current injection in the case of grid faults. A Doubled Decoupled Synchronous Reference Frame Phase Locked Loop (DDSRF-PLL) for Vector Current Control (VCC) is implemented. Additionally, a Fault Detection and Fault Ride-Through Reference Generator with a Current Limitation strategy is introduced. Though these techniques are well described in the literature, the DDSRF is improved for current control stability. The relationship between the parameters of the PLL and the control, as well as the behaviour of the protection system, are demonstrated. Grid faults with large voltage dips pose a significant challenge to the stability of the control system. Nevertheless, it is shown that with the developed model, it is possible to make general statements about the protection behaviour in an inverter-based environment.
Related Concept Videos
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
Transformers with Off-Nominal Turns Ratios
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Power System Three-Phase Short Circuits
Multimachine Stability
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:

