Introduction:
This study compares home-based oscillometry and spirometry for characterizing respiratory system disease in school-aged children with bronchopulmonary dysplasia (BPD) in clinical research. We hypothesized higher rates of successful completion and abnormal cases identified through oscillometry, with correlations between device measurements.
Methods:
Participants 6-12 years old with BPD in the ongoing Air Quality, Environment and Respiratory Outcomes in BPD (AERO-BPD) study performed oscillometry followed by spirometry at two separate home visits. Parameters measured included airway resistance at 5 Hz(R5), resistance from 5 to 19 Hz(R5-19), resonance frequency(Fres), reactance at 5 Hz(X5), area under the curve between Fres and X5(AX), forced expiratory volume in 1 second(FEV1), forced vital capacity(FVC), and FEV1/FVC. Descriptive statistics identified the proportion of successful tests, correlation in measurements, and rate of lung disease for each device.
Results:
Among 76 subjects with 120 paired observations, 95% and 71% of participants successfully performed oscillometry and spirometry, respectively, at home visit one. 98% and 77% successfully performed oscillometry and spirometry, respectively, at home visit two. Odds ratios favored oscillometry (range 5.31-10.13, p < 0.01). FEV1 correlated with AX (correlation coefficient r = -0.27, p = 0.03); FEV1/FVC with AX (r = -0.32, p = 0.02); and FEV1/FVC with R5 (r = -0.37, p = 0.01). AX exhibited the highest prevalence of abnormality at 25%; other oscillometry parameters ranged from 5%-22%. Forty-five to sixty-four percent of participants had abnormal spirometry. Oscillometry assessments had significantly lower odds of capturing lung disease (odds ratios 0.07-0.24, p < 0.0001).
Conclusions:
School-aged children with BPD demonstrated higher success rates in field-based oscillometry than spirometry. Spirometry exhibited higher rates of abnormality than oscillometry. Moderate correlation exists between device measurements.
Related Concept Videos
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Chronic Obstructive Pulmonary Disease-I: Introduction
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
COPD: Management Using Bronchodilators and Corticosteroids
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...