Related Experiment Video
Updated: Jun 24, 2025

Author Spotlight: Fu's Subcutaneous Needling for Knee Osteoarthritis Pain
Published on: March 24, 2023
Physiological Biomarkers for Assessment of Pain during Routine Blood Tests for Older Adults with Dementia in
Po-Chung Feng1, Mohammad Anwar Khan2, Ting-Ting Yeh3
1Master Degree Program in Health and Long-term Care Industry, College of Medicine, Chang Gung University, Taoyuan, Taiwan; Department of Internal Medicine, National Taiwan University Hospital Hsinchu Branch, Hsinchu, Taiwan.
Objective:
Evaluating pain in individuals with dementia can be difficult when verbal communication is limited. Vocalization has emerged as a potential avenue for assessments of pain in nonverbal populations. This study aimed to evaluate if physiological assessments of vocalization were correlated with observational assessments of pain during routine blood tests for persons with dementia.
Design:
A cross-sectional descriptive study.
Setting And Participants:
Sixty older adults (aged ≥65 years old) with dementia requiring routine finger puncture and peripheral venipuncture for routine blood tests were recruited by purposive sampling from 3 long-term care facilities in Taiwan.
Methods:
Observational assessments were conducted with the Pain Assessment in Advanced Dementia (PAINAD) instrument; physiological biomarkers of vocalization were assessed with a noninvasive sensing device and microphone (NISDM). Assessments were conducted simultaneously in one session during situations of increasing pain levels: at rest, making a sound, finger puncture, and peripheral venipuncture. PAINAD scores were compared with signal recording measures from the NISDM. Analysis of variance and Pearson correlation coefficient assessed correlations between observational and physiological measures.
Results:
Most participants were female (63.3%); mean age was 81.27 years (SD = 9.69); Clinical Dementia Rating was 2.23 ± 0.70; and Mini-Mental State Examination was 7.07 ± 6.95. Signal recording measures using the NISDM during finger puncture and venipuncture were significantly greater compared with measures at rest and making sound, indicating higher signal levels were associated with pain. PAINAD scores were significantly correlated with physiological measures for vocalization variables of sound amplitude (r = 0.49, P < .001), shimmer (r = 0.63, P < .001), and inhalation-to-exhalation amplitude ratio (r = 0.48, P < .001).
Conclusions And Implications:
Elevated vocalizations detected with the NISDM were correlated with increased pain scores on the PAINAD instrument. Physiological measures of pain using novel vocalization biomarkers have the potential to enhance the quality of care for individuals with dementia and limited communication abilities.
More Related Videos
09:38Determining Pain Detection and Tolerance Thresholds Using an Integrated, Multi-Modal Pain Task Battery
Published on: April 14, 2016
06:04Objective Nociceptive Assessment in Ventilated ICU Patients: A Feasibility Study Using Pupillometry and the Nociceptive Flexion Reflex
Published on: July 4, 2018
Related Concept Videos
Blood Studies for Cardiovascular System II: CRP, Hcy, and Cardiac Natriuretic Peptide Markers
These markers indicate stress or strain on the heart muscle:
Natriuretic Peptides (BNP)
Cardiac myocytes produce these hormones in response to ventricular stretching...
Pre-Procedural Guidelines for Assessing Blood Pressure
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: