Developing a three stage coordinated approach to enhance efficiency and reliability of virtual power plants

Jeremiah Amissah1, Omar Abdel-Rahim1,2, Diaa-Eldin A Mansour1,3

  • 1Electrical Power Engineering Department, Egypt-Japan University of Science and Technology, New Borg El-Arab City, 21934, Alexandria, Egypt.

Scientific Reports
|June 7, 2024
PubMed

Related Concept Videos

Control of Power Flow01:30

Control of Power Flow

There are several methods to control power flow in power systems:
265
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the...
200
Three-Phase Circuits01:22

Three-Phase Circuits

AC power distribution systems have three categories: single-phase, two-phase, and three-phase systems. The single-phase circuit, common in residential settings, typically employs a two-wire system connecting a single AC source to various loads. These circuits support standard household appliances operating at 120 volts (V) and 240 V, such as lamps, televisions, and microwaves. The first generators, Niagara Falls hydro plant installed in 1895, were two-phase and designed by Nikola Tesla. The...
399
Multimachine Stability01:25

Multimachine Stability

Multimachine stability analysis is crucial for understanding the dynamics and stability of power systems with multiple synchronous machines. The objective is to solve the swing equations for a network of M machines connected to an N-bus power system.
In analyzing the system, the nodal equations represent the relationship between bus voltages, machine voltages, and machine currents. The nodal equation is given by:
151
Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
107
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
187