Related Experiment Video
Updated: Jun 24, 2025

Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Post-processing of a 3D-printed denture base polymer: Impact of a centrifugation method on the surface
Jingtao Dai1, Ke Luo2, Qian Liu2
1Department of Orthodontics, Stomatological Hospital, School of Stomatology, Southern Medical University, South Jiangnan Road No. 366, Guangzhou 510280, China.
Objectives:
To investigate the impact of a centrifugation method on the surface characteristics, flexural properties, and cytotoxicity of an additively manufactured denture base polymer.
Methods:
The tested specimens were prepared by digital light processing (DLP). A centrifugation method (CENT) was used to remove the residual uncured resin. In addition, the specimens were post-processed with different post-rinsing solutions: isopropanol (IPA), ethanol (EtOH), and tripropylene glycol monomethyl ether (TPM), respectively. A commercial heat-polymerized polymethyl methacrylate was used as a reference (REF). First, the values of surface topography, arithmetical mean height (Sa), and root mean square height (Sq) were measured. Next, flexural strength (FS) and modulus were evaluated. Finally, cytotoxicity was assessed using an extract test. The data were statistically analyzed using a one-way analysis of variance, followed by Tukey's multiple comparison test for post-hoc analysis.
Results:
The Sa value in the CENT group was lower than in the IPA, EtOH, TPM, and REF groups (p < 0.001). Moreover, the CENT group had lower Sq values than other groups (p < 0.001). The centrifugation method showed a higher FS value (80.92 ± 8.65 MPa) than the EtOH (61.71 ± 12.25 MPa, p < 0.001) and TPM (67.01 ± 9.751 MPa, p = 0.027), while affecting IPA (72.26 ± 8.80 MPa, p = 0.268) and REF (71.39 ± 10.44 MPa, p = 0.231). Also, the centrifugation method showed no evident cytotoxic effects.
Conclusions:
The surfaces treated with a centrifugation method were relatively smooth. Simultaneously, the flexural strength of denture base polymers was enhanced through centrifugation. Finally, no evident cytotoxic effects could be observed from different post-processing procedures.
Clinical Significance:
The centrifugation method could optimize surface quality and flexural strength of DLP-printed denture base polymers without compromising cytocompatibility, offering an alternative to conventional rinsing post-processing.