Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Instrument Calibration01:12

Instrument Calibration

177
Instrument calibration is essential for ensuring that instruments produce accurate and consistent results. It is vital in manufacturing, healthcare, testing laboratories, and scientific research. Calibration processes are specific to each instrument and help enhance data accuracy. Each instrument has a unique calibration process tailored to its design and function to improve data accuracy.
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
177

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

CNN-based nonlinearity correction and background radiation suppression of an infrared spectral radiance measurement system.

Applied optics·2026
Same author

Measurement of 0/45 reflectance factor using nonlinearity corrected array spectroradiometer.

Optics express·2026
Same author

Influence of Multi-Cue Interaction on Human Depth Perception in Three-Dimensional Space.

Sensors (Basel, Switzerland)·2026
Same author

Tryptophan metabolites 3-hydroxykynurenine (3HK) and 3-hydroxyanthranilic acid (3HAA) increase oxidative stress and impair osteoblastic bone formation.

The Journal of biological chemistry·2026
Same author

Integrating 3D Osteocyte Culture, Microgravity Simulation, and Fluid Flow Reveals Mechanisms of Osteocyte Mechanosensation and Calcium Signaling Altered by Disuse.

Biomolecules·2025
Same author

A Modified Two-Temperature Calibration Method and Facility for Emissivity Measurement.

Materials (Basel, Switzerland)·2025

Related Experiment Video

Updated: Jun 24, 2025

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
09:18

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident

Published on: December 14, 2017

10.4K

Facility for spectral radiance calibration at low light level.

Zhifeng Wu, Qiming Wang, Caihong Dai

    Optics Express
    |June 11, 2024
    PubMed
    Summary

    Accurate nighttime spectral radiance calibration is challenging. This study introduces a novel facility enabling precise calibration of spectroradiometers at low light levels, crucial for nighttime measurements.

    More Related Videos

    A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
    06:06

    A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements

    Published on: July 19, 2016

    9.5K
    Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
    09:41

    Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron

    Published on: June 9, 2016

    12.4K

    Related Experiment Videos

    Last Updated: Jun 24, 2025

    Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
    09:18

    Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident

    Published on: December 14, 2017

    10.4K
    A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements
    06:06

    A Simple Dewar/Cryostat for Thermally Equilibrating Samples at Known Temperatures for Accurate Cryogenic Luminescence Measurements

    Published on: July 19, 2016

    9.5K
    Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron
    09:41

    Emission Spectroscopic Boundary Layer Investigation during Ablative Material Testing in Plasmatron

    Published on: June 9, 2016

    12.4K

    Area of Science:

    • Metrology
    • Optical Engineering
    • Radiometry

    Background:

    • Accurate spectral radiance measurements are vital for various applications.
    • Nighttime spectral radiance calibration presents significant technical challenges compared to daytime levels.
    • Existing calibration methods often lack the required precision for low-light conditions.

    Purpose of the Study:

    • To design and develop a spectral radiance calibration facility capable of high-accuracy measurements at nighttime levels.
    • To enable the reproduction of spectral radiance across a wide dynamic range, specifically for low-light conditions.
    • To reduce the calibration uncertainty for spectroradiometers operating in nighttime spectral radiance ranges.

    Main Methods:

    • Development of a spectral radiance calibration facility integrating a stable light source, precision aperture, and white diffuser.
    • Characterization of the facility's spectral stability over multiple orders of magnitude.
    • Utilization of the facility to calibrate a spectroradiometer at nighttime spectral radiance levels (380 nm to 780 nm).

    Main Results:

    • The developed facility exhibits an unchanged spectrum over 3 orders of magnitude and approximately unchanged spectrum over 6 orders of magnitude.
    • The facility can reproduce spectral radiance at 380 nm from 4 × 10-9 W/(m2·sr·nm) to 4 × 10-3 W/(m2·sr·nm).
    • Spectroradiometer calibration uncertainty was achieved at 0.87%–1.0% (k=1) for spectral radiance around 1 × 10-7 W/(m2·sr·nm) between 380 nm and 780 nm.

    Conclusions:

    • The novel spectral radiance calibration facility effectively addresses the challenges of nighttime low-light measurements.
    • The facility provides a reliable and accurate method for calibrating spectroradiometers, significantly improving measurement precision.
    • This advancement is critical for applications requiring sensitive nighttime spectral radiance detection and analysis.