Related Experiment Video
Updated: May 14, 2026

A New Single Chamber Implantable Defibrillator with Atrial Sensing: A Practical Demonstration of Sensing and Ease of Implantation
Published on: February 28, 2012
Implantable Cardioverter-Defibrillator Placement in Spontaneous Coronary Artery Dissection: A Case Report
Jimmy Hong1, Jeremy C Tomcho1, Steven L Mai2
1Division of Cardiovascular Medicine, University of Texas Medical Branch, Galveston, TX, USA.
Abstract:
BACKGROUND Spontaneous coronary artery dissection can present with acute coronary syndrome, ventricular arrhythmias, or sudden cardiac death. Implantable cardioverter-defibrillator placement in patients with spontaneous coronary artery dissection is controversial. The purpose of publishing this case is to inform physicians of potential benefits of implantable cardioverter-defibrillator implantation in patients with spontaneous coronary artery dissection. CASE REPORT A 55-year-old woman presented with chest pain, with an electrocardiogram revealing anterior ST-elevation myocardial infarction and troponin peak of 53.8 ng/mL. Coronary angiography revealed mid-left anterior descending artery occlusion, with appearance of spontaneous coronary artery dissection that was not amenable to revascularization. The decision was made to treat medically. In recovery, the patient experienced ventricular fibrillation arrest. The patient was defibrillated once with achievement of return of spontaneous circulation. An Impella CP was placed to stabilize the patient. After the patient was stabilized, an implantable cardioverter-defibrillator was placed. CONCLUSIONS Data on potential benefits of implantable cardioverter-defibrillator placement in patients with spontaneous coronary artery dissection are limited. Most patients with spontaneous coronary artery dissection recover normal coronary architecture; however, there are no guidelines for implantable cardioverter-defibrillator placement in patients with spontaneous coronary artery dissection. Patients with spontaneous coronary artery dissection with high-risk features may benefit from implantable cardioverter-defibrillator for secondary prevention of ventricular arrhythmia and sudden cardiac death, as shown with this case.
More Related Videos
07:41Insertion, Maintenance, and Removal of the Percutaneous Dual Lumen Cannula Right Ventricular Assist Device
Published on: July 20, 2022
08:42Cox-Maze IV Procedure Concomitant with Valvular Surgery In Situs Inversus Dextrocardia: A Single-Center Experience in China
Published on: February 11, 2022