Related Experiment Video
Updated: Jun 24, 2025

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Identifying time-varying dynamics of heart rate and oxygen uptake from single ramp incremental running tests
Jasper Gielen1, Loes Stessens1, Romain Meeusen2
1Biosystems Department, Research Group M3-BIORES, KU Leuven, 3001 Leuven, Belgium.
Abstract:
Objective.The fact that ramp incremental exercise yields quasi-linear responses for pulmonary oxygen uptake (V˙O2) and heart rate (HR) seems contradictory to the well-known non-linear behavior of underlying physiological processes. Prior research highlights this issue and demonstrates how a balancing of system gain and response time parameters causes linearV˙O2responses during ramp tests. This study builds upon this knowledge and extracts the time-varying dynamics directly from HR andV˙O2data of single ramp incremental running tests.Approach.A large-scale open access dataset of 735 ramp incremental running tests is analyzed. The dynamics are obtained by means of 1st order autoregressive and exogenous models with time-variant parameters. This allows for the estimates of time constant (τ) and steady state gain (SSG) to vary with work rate.Main results.As the work rate increases,τ-values increase on average from 38 to 132 s for HR, and from 27 to 35 s forV˙O2. Both increases are statistically significant (p< 0.01). Further, SSG-values decrease on average from 14 to 9 bpm (km·h-1)-1for HR, and from 218 to 144 ml·min-1forV˙O2(p< 0.01 for decrease parameters of HR andV˙O2). The results of this modeling approach are line with literature reporting on cardiorespiratory dynamics obtained using standard procedures.Significance.We show that time-variant modeling is able to determine the time-varying dynamics HR andV˙O2responses to ramp incremental running directly from individual tests. The proposed method allows for gaining insights into the cardiorespiratory response characteristics when no repeated measurements are available.
Related Concept Videos
Factors Influencing Heart Rate
Let us explore the significant factors affecting heart rate, including age, body temperature, posture, acute pain, chemical influences,...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Regulation of Heart Rates
The SNS increases heart rate through the release of norepinephrine and epinephrine, which act on beta-1 adrenergic receptors in the heart. This action increases the rate of depolarization in the sinoatrial (SA) node, the heart's...
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Pathophysiology of Cardiac Performance