Related Experiment Video
Updated: Jun 24, 2025

Quadruple-Checkerboard: A Modification of the Three-Dimensional Checkerboard for Studying Drug Combinations
Published on: July 24, 2021
Physical compatibility of ceftriaxone and cefepime in 0.45% sodium chloride, Ringer's lactate solution, and
Megan Kelley1, Chloe Spooneybarger1, Mitchell Howard1
1The University of Toledo College of Pharmacy and Pharmaceutical Sciences, Toledo, Ohio, USA.
Objectives:
The compatibility of intravenous fluids with medications is of paramount concern to pharmacists and is an imperative component of ensuring patient safety. Data regarding the physical compatibility of medications with intravenous fluids has not been examined, or published with conflicting results or the concentrations studied were not consistent with current practice. Our objective was to determine the physical compatibility of ceftriaxone and cefepime in 0.45% sodium chloride, Ringer's lactate solution, and Plasma-Lyte A.
Methods:
An in vitro analysis of the physical compatibility of ceftriaxone and cefepime at 10 mg/mL, 20 mg/mL, and 40 mg/mL concentrations was conducted in 0.45% sodium chloride, Ringer's lactate solution, and Plasma-Lyte A. Admixtures were evaluated in triplicate at hours 0, 1, 5, 8, and 24. Physical compatibility was assessed by visual inspection, spectrophotometry, and pH analysis.
Results:
Ceftriaxone 40 mg/mL was found to be physically incompatible in 0.45% sodium chloride and Ringer's lactate solution beyond 5 hours and in Plasma-Lyte A beyond 8 hours. Cefepime was found to be physically incompatible with all fluids and in all concentrations beyond 1 hour.
Conclusions:
This work contributes to the body of literature dedicated to the evaluation of intravenous drug and fluid physical compatibility by identifying demonstrable changes in admixtures containing 0.45% sodium chloride, Plasma-Lyte A, and Ringer's lactate solution. Ceftriaxone should not be administered with 0.45% sodium chloride, Ringer's lactated solution, or Plasma-Lyte A at selected concentrations and time points and cefepime is not considered to be physically compatible at 10 mg/mL, 20 mg/mL, or 40 mg/mL in any of the studied fluids beyond 1 hour.
More Related Videos
11:17Multiplex Therapeutic Drug Monitoring by Isotope-dilution HPLC-MS/MS of Antibiotics in Critical Illnesses
Published on: August 30, 2018
12:03Antimicrobial Synergy Testing by the Inkjet Printer-assisted Automated Checkerboard Array and the Manual Time-kill Method
Published on: April 18, 2019
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Precipitation of Ions
The equation that describes the equilibrium between solid calcium carbonate and its solvated ions is:
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted...
Solubility Equilibria
The...