[Design and Testing of a Pressure Measurement and Adjustment Device for Fracture Ends]

Zhongyuan Shen1, Yizhe Fan1, Xiao Zhang1

  • 1The First Clinical Medical College, Nanjing University of Chinese Medicine, Nanjing, 210023.

Abstract

Related Concept Videos

Design Example: Strain Gauge Bridge or Wheatstone Bridge01:15

Design Example: Strain Gauge Bridge or Wheatstone Bridge

The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
1.3K
Stress-Strain Diagram01:10

Stress-Strain Diagram

A stress-strain diagram is a crucial tool that graphically displays a material's mechanical characteristics. This diagram is derived from a tensile test performed on a carefully prepared cylindrical specimen. The specimen has two gauge marks inscribed on its central part, and the distance between these marks is known as the gauge length. The cylindrical specimen is placed in a testing machine, which applies an increasing centric load. As this load grows, so does the gauge length. This...
6.9K
Measurements of Strain01:27

Measurements of Strain

Strain quantifies the deformation of a material under force, typically measured as normal strain, which represents the change in length when compared with the original length. Electrical strain gauges are used for enhanced accuracy. These devices consist of a conductive wire mounted on a paper backing that adheres to the material's surface. These gauges operate on the piezoresistive effect, where the wire's electrical resistance changes in response to mechanical deformation. The strain...
2.8K
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
703
Circuit Breaker and Fuse Selection01:23

Circuit Breaker and Fuse Selection

A circuit breaker is a device engineered to interrupt fault currents and sometimes reclose automatically. When a fault current is detected, the breaker separates the electrical contacts, which generates an arc. This arc is extinguished by methods such as elongation, cooling, or splitting, depending on the breaker's design. Breakers are categorized based on the voltage they operate at and the medium used for arc extinction, such as air, oil, SF6 gas, or vacuum.
In high-voltage systems,...
747
Bioreactor Controls-I01:28

Bioreactor Controls-I

Maintaining optimal conditions within fermenters is essential for maximizing microbial productivity and ensuring process efficiency. This lesson focuses on key parameters—temperature, foam, pH, carbon dioxide, oxygen, and pressure—and their precise measurement and control strategies in fermentation systems.Temperature ControlTemperature regulation is critical due to the exothermic nature of many fermentation processes. In small laboratory fermenters, temperature is commonly...
94