Background:
Medication errors in the operating room have high potential for patient harm. While electronic clinical decision support (CDS) software has been effective in preventing medication errors in many nonoperating room patient care areas, it is not yet widely used in operating rooms. The purpose of this study was to determine the percentage of self-reported intraoperative medication errors that could be prevented by CDS algorithms.
Methods:
In this retrospective cross-sectional study, we obtained safety reports involving medication errors documented by anesthesia clinicians between August 2020 and August 2022 at a 1046-bed tertiary care academic medical center. Reviewers classified each medication error by its stage in the medication use process, error type, presence of an adverse medication event, and its associated severity and preventability by CDS. Informational gaps were corroborated by retrospective chart review and disagreements between reviewers were resolved by consensus. The primary outcome was the percentage of errors that were preventable by CDS. Secondary outcomes were preventability by CDS stratified by medication error type and severity.
Results:
We received 127 safety reports involving 80 medication errors, and 76/80 (95%) of the errors were classified as preventable by CDS. Certain error types were more likely to be preventable by CDS than others ( P < .001). The most likely error types to be preventable by CDS were wrong medication (N = 36, 100% rated as preventable), wrong dose (N = 30, 100% rated as preventable), and documentation errors (N = 3, 100% rated as preventable). The least likely error type to be preventable by CDS was inadvertent bolus (N = 3, none rated as preventable).
Conclusions:
Ninety-five percent of self-reported medication errors in the operating room were classified as preventable by CDS. Future research should include a randomized controlled trial to assess medication error rates and types with and without the use of CDS.
More Related Videos
Related Concept Videos
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Documentation of Nursing Diagnosis
In some settings, data-driven computerized decision support systems are in place, allowing for more accurate nursing diagnoses. The database within one of these systems includes diagnostic labels defining characteristics, activities, and indicators for nursing. A nurse enters...
Methods of Documentation VI: Case Management Model
For example, a patient with a chronic...
Guidelines and Strategies for Safe Computer Charting
Maintain Confidentiality and Security:
Errors occurring during blood pressure monitoring
Several factors...
SBAR II: Application of SBAR
SBAR Report from a Nurse to a Health Care Provider
S: "Hello, Dr. Smith. This is Jane, RN, from the Med Surg unit. I am calling to tell you about Ms. White in Room 210, who is experiencing increased pain and redness at her incision site. Her recent...