Related Experiment Video
Updated: Jun 23, 2025

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
Simplification strategies for a patient-specific CFD model of particle transport during liver radioembolization
Tim Bomberna1, Geert Maleux2, Charlotte Debbaut1
1IBiTech-BioMMedA, Department of Electronics and Information Systems, Ghent University, Ghent, Belgium; Cancer Research Institute Ghent, Ghent, Belgium.
Background:
Patient-specific 3D computational fluid dynamics (CFD) simulations have been used previously to identify the impact of injection parameters (e.g. injection location, velocity, etc.) on the particle distribution and the tumor dose during transarterial injection of radioactive microspheres for treatment of hepatocellular carcinoma. However, these simulations are computationally costly, so we aim to evaluate whether these can be reliably simplified.
Methods:
We identified and applied five simplification strategies (i.e. truncation, steady flow modelling, moderate and severe grid coarsening, and reducing the number of cardiac cycles) to a patient-specific CFD setup. Subsequently, we evaluated whether these strategies can be used to (1) accurately predict the CFD output (i.e. particle distribution and tumor dose) and (2) quantify the sensitivity of the model output to a specific injection parameter (injection flow rate).
Results:
For both accuracy and sensitivity purposes, moderate grid coarsening is the most reliable simplification strategy, allowing to predict the tumor dose with only a maximal deviation of 1.4 %, and a similar sensitivity (deviation of 0.7 %). The steady strategy performs the worst, with a maximal deviation in the tumor dose of 20 % and a difference in sensitivity of 10 %.
Conclusion:
The patient-specific 3D CFD simulations of this study can be reliably simplified by coarsening the grid, decreasing the computational time by roughly 45 %, which works especially well for sensitivity studies.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Related Concept Videos
Physiological Pharmacokinetic Models: Incorporating Hepatic Transporter-Mediated Clearance
A recent model describes pravastatin's hepatobiliary excretion,...
Physiological Pharmacokinetic Models: Blood Flow-Limited Versus Diffusion-Limited Models
Three-Compartment Open Model
Compartment Models: Single-Compartment Model
Multicompartment Models: Overview
These models offer a more comprehensive representation of drug behavior in the body than one-compartment models. They accommodate the complexity of drug distribution,...