Related Experiment Video
Updated: Jun 23, 2025

The Pilocarpine Model of Temporal Lobe Epilepsy and EEG Monitoring Using Radiotelemetry System in Mice
Published on: February 27, 2018
Rat strain differences in seizure frequency and hilar neuron loss after systemic treatment with pilocarpine
Kristina Junghans1, Megan Wyeth1, Paul S Buckmaster2
1Departments of Comparative Medicine, Stanford University, 3172 Porter Drive, Palo Alto, CA 94304-5475, USA.
Abstract:
At least 3 months after systemic treatment with pilocarpine to induce status epilepticus, Long-Evans and Sprague-Dawley rats were video-EEG monitored for seizures continuously for 1 month. Rats were then perfused, hippocampi were processed for Nissl staining, and hilar neurons were quantified. Seizure frequency in Long-Evans rats was 1/10th of that in Sprague-Dawley rats, and more variable. Hilar neuron loss was also less severe in Long-Evans rats. However, there was no correlation between hilar neuron loss and seizure frequency in either strain. The low and variable seizure frequency suggests limited usefulness of pilocarpine-treated Long-Evans rats for some epilepsy experiments.