Related Experiment Video
Updated: May 5, 2026

Prehospital Thrombolysis: A Manual from Berlin
Published on: November 26, 2013
Intensive versus less intensive blood pressure targets after mechanical thrombectomy in acute ischemic stroke: a
Bruno Felipe Santos de Oliveira1, Rafaela Góes Bispo2, Bruna Helena Ribeiro Araújo Dos Santos2
1Faculty of Medicine of Bahia, Federal University of Bahia, Bahia, Brazil. bruno.oliveiraphysci@gmail.com.
Hemodynamic management, specifically blood pressure, is essential to reduce mortality and preserve functional capacity. However, the literature is uncertain about the best blood pressure target to be adopted after performing mechanical thrombectomy in patients with acute ischemic stroke. Randomized clinical trials that compared blood pressure goals after mechanical thrombectomy were searched in the following databases: MEDLINE/PubMed, Embase, Scopus, Biomedcentral, and Cochrane Library. The last search was on September 19, 2023. The results obtained were used to construct network meta-analyses. A total of 1556 participants were enrolled from 4 randomized controlled trials (OPTIMAL-BP, ENCHANTED2/MT, BP-TARGET, BEST-II). The last article was not included in the network meta-analysis because it did not have common blood pressure targets. The outcomes compared were: mRS (modified Rankin scale), eTICI/mTICI scale scores, symptomatic and any intracerebral hemorrhage, post-intervention NIHSS, and post-intervention infarct volume. The outcomes using the mRS scale showed that better outcomes were reached with less intensive blood pressure targets when comparing < 120 mmHg vs. ≤ 180 mmHg, OR: 0.71 (95% CI 0.54 - 0.94), in the outcome of mRS 0-1. And for the mRS 0-2 outcome with comparisons < 120 mmHg vs. ≤ 180 mmHg, with OR: 0.59 (95% CI 0.44 - 0.77) and < 140 mmHg vs. ≤ 180 mmHg, with OR: 0.61 (95% CI 0.41 - 0.89). In patients with large vessel occlusion treated with mechanical thrombectomy and who achieved good reperfusion, intensive blood pressure lowering is not effective and might be harmful respect to non intensive blood pressure control in recanalized patients.
Hemodynamic management, specifically blood pressure, is essential to reduce mortality and preserve functional capacity. However, the literature is uncertain about the best blood pressure target to be adopted after performing mechanical thrombectomy in patients with acute ischemic stroke. Randomized clinical trials that compared blood pressure goals after mechanical thrombectomy were searched in the following databases: MEDLINE/PubMed, Embase, Scopus, Biomedcentral, and Cochrane Library. The last search was on September 19, 2023. The results obtained were used to construct network meta-analyses. A total of 1556 participants were enrolled from 4 randomized controlled trials (OPTIMAL-BP, ENCHANTED2/MT, BP-TARGET, BEST-II). The last article was not included in the network meta-analysis because it did not have common blood pressure targets. The outcomes compared were: mRS (modified Rankin scale), eTICI/mTICI scale scores, symptomatic and any intracerebral hemorrhage, post-intervention NIHSS, and post-intervention infarct volume. The outcomes using the mRS scale showed that better outcomes were reached with less intensive blood pressure targets when comparing < 120 mmHg vs. ≤ 180 mmHg, OR: 0.71 (95% CI 0.54 - 0.94), in the outcome of mRS 0-1. And for the mRS 0-2 outcome with comparisons < 120 mmHg vs. ≤ 180 mmHg, with OR: 0.59 (95% CI 0.44 - 0.77) and < 140 mmHg vs. ≤ 180 mmHg, with OR: 0.61 (95% CI 0.41 - 0.89). In patients with large vessel occlusion treated with mechanical thrombectomy and who achieved good reperfusion, intensive blood pressure lowering is not effective and might be harmful respect to non intensive blood pressure control in recanalized patients.
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care
Ischemic Stroke ll: Pathophysiology

