Related Experiment Video
Updated: Jun 23, 2025

Using Extraordinary Optical Transmission to Quantify Cardiac Biomarkers in Human Serum
Published on: December 13, 2017
Highly Sensitive Immunoassay for Long Forms of Cardiac Troponin T Using Upconversion Luminescence
Selma M Salonen1, Tuulia J K Tuominen1, Kirsti I S Raiko1
1Biotechnology Unit, Department of Life Technologies, University of Turku, Turku, Finland.
Background:
Long cardiac troponin T (cTnT) has been proposed to be a promising and more specific biomarker of acute myocardial infarction (AMI). As it represents a subfraction of circulating cTnT, detection of very low concentrations is a requirement. The aim of this study was to develop a novel, highly sensitive immunoassay for long cTnT.
Methods:
A two-step sandwich-type immunoassay for long cTnT was developed, utilizing upconverting nanoparticles (UCNPs) as reporters. The limits of detection and quantitation were determined for the assay. Linearity and matrix effects were evaluated. Performance with clinical samples was assessed with samples from patients with non-ST elevation myocardial infarction (NSTEMI, n = 30) and end-stage renal disease (ESRD, n = 37) and compared to a previously developed time-resolved fluorescence (TRF)-based long cTnT assay and a commercial high-sensitivity cTnT assay.
Results:
The novel assay reached a 28-fold lower limit of detection (0.40 ng/L) and 14-fold lower limit of quantitation (1.79 ng/L) than the previously developed TRF long cTnT assay. Li-heparin and EDTA plasma, but not serum, were found to be suitable sample matrixes for the assay. In a receiver operating characteristics curve analysis, the troponin ratio (long/total cTnT) determined with the novel assay showed excellent discrimination between NSTEMI and ESRD with an area under the curve of 0.986 (95% CI, 0.967-1.000).
Conclusions:
By utilizing upconversion luminescence technology, we developed a highly sensitive long cTnT assay. This novel assay can be a valuable tool for investigating the full potential of long cTnT as a biomarker for AMI. ClinicalTrials.gov Registration Number: NCT04465591.
More Related Videos
10:12A Sensitive and Specific Quantitation Method for Determination of Serum Cardiac Myosin Binding Protein-C by Electrochemiluminescence Immunoassay
Published on: August 8, 2013
07:12Time-resolved Förster Resonance Energy Transfer Assays for Measurement of Endogenous Phosphorylated STAT Proteins in Human Cells
Published on: September 9, 2021
Related Concept Videos
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...
Photoluminescence: Applications