Related Experiment Video
Updated: Jun 23, 2025

Ultrasound Cyclo Plasty in Eyes with Glaucoma
Published on: January 26, 2018
Performance of home-based self-tonometry (iCare HOME (TA022)) for measuring intraocular pressure among healthy and
Anush Nayak1,2, S Ve Ramesh2, Neetha I R Kuzhuppilly3
1Department of Allied Health Sciences,Faculty of Life & Allied Health Sciences(FLAHS), Ramaiah University of Applied Sciences, Bangalore, Karnataka, 560054, India.
Abstract:
Introduction: The purpose of this study was to compare iCare HOME (TA022) with Goldmann applanation tonometer and to evaluate the self-tonometry measurements among the Indian population. Methods: Eligible patients underwent iCare HOME training through guided demonstration (verbal, pictorial, video) and practised self-tonometry measures using iCare HOME. Certification for independent iCare HOME measure was provided if first iCare HOME intraocular pressure (IOP) measurement fell within ± 5 mmHg of Goldmann applanation tonometer (GAT) measurement which was measured by the trained clinician (principal investigator). Certified participants underwent simulated home self-tonometry measurements using iCare HOME, and agreement with GAT IOP measurements was assessed. Results: Seven of 83 participants (8.43%) failed to complete the study due to difficulty in performing the task, leading to non-certification. Patients who could use the iCare HOME had a mean age of 53 ± 15.55years (53% males; 46% females). Only one in 12 subjects did not qualify to use iCare HOME. The overall mean difference between iCare HOME and GAT was 0.83 mmHg (95%, 3.92 and -2.25). At various pressure ranges, 7-16 mmHg, 17-23 mmHg and >23 mmHg, the mean difference between iCare HOME and GAT was 1.22 mmHg (95%, 4.32 and -1.86), 0.77 mmHg (95%,3.69 and -2.19), -0.11 mmHg (95%, 2.52 and -2.74) respectively. The intra-class correlation coefficient of the iCare HOME device was 0.997(95% CI,0.995-0.998). Conclusions: Patients were able to perform self- tonometry using iCare HOME with good reliability and safety. iCare HOME can be used to address the issue of difficulty in acquiring frequent and diurnal IOP measurements by patients doing self-tonometry from home.
Related Concept Videos
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Glaucoma: Overview
Angle Closure Glaucoma: Treatment
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Pre-Procedural Guidelines for Assessing Blood Pressure