Three-Dimensional Anthropometric Facial Analysis and Fitting Discrepancies Between Stereophotogrammetry and CT
Wenqing Han1, Yingjie Yan1, Sriya Nemani2
1From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Annals of Plastic Surgery
|June 19, 2024
Summary
3D CT and stereophotogrammetry are reliable for facial soft tissue analysis. However, mandibular angle (Go-Go) measurements differ significantly between methods due to positional factors, requiring careful consideration.
Area of Science:
- Anthropometry
- Medical Imaging
- Biotechnology
Background:
- Investigated the reliability and repeatability of stereophotogrammetry and computed tomography (CT) in 3-dimensional anthropometric facial analysis.
- Explored the clinical application of supine CT for facial measurements.
Purpose of the Study:
- To compare the reliability and accuracy of 3D CT and 3dMD stereophotogrammetry for facial anthropometric analysis.
- To identify optimal landmark points for registration in 3D facial analysis.
Main Methods:
- 20 healthy volunteers underwent 3D CT and 3dMD stereophotogrammetry.
- Measurements included facial landmarks (Al-Al), width (Go-Go, Zy-Zy, Ex-Ex), and height (Sn-Gn).
- Intraclass correlation coefficient (ICC) assessed interrater reliability; paired t-analysis evaluated intramethod displacement.
Main Results:
- Alare, nasion, and pronasale points showed minimal positional influence, recommended for registration.
- CT exhibited good interrater reliability across all indicators.
- Stereophotogrammetry showed ICC < 0.75 for Go-Go and Zy-Zy. Significant differences (P < 0.05) between CT and stereophotogrammetry were found for En-En, Ex-Ex, and Go-Go, with CT yielding a larger Go-Go measurement by 2.34 mm.
Conclusions:
- Both CT and stereophotogrammetry are reliable for facial soft tissue evaluation.
- The Go-Go measurement discrepancy is attributed to positional variations, facial expressions, and gravity.
- Careful consideration of these factors is crucial when evaluating the mandibular angle region.