Related Experiment Video
Updated: May 9, 2026

Thinned-skull Cortical Window Technique for In Vivo Optical Coherence Tomography Imaging
Published on: November 19, 2012
Optical Coherence Tomography Advanced Parameters in Patients With Multiple Sclerosis: Ophthalmological and
Maria Cristina Savastano1, Viviana Nociti2, Federico Giannuzzi1
1From the Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS (M.C.S., F.G., V.C., M.M.C., C.F., S.R.), Rome, Italy; Catholic University of the Sacred Heart (M.C.S., V.N., F.G., V.C., M.M.C., C.F., I.B., S.R.), Rome, Italy.
Purpose:
To evaluate ophthalmological, neurological, radiological, and laboratory data in patients with multiple sclerosis (MS) and to identify new ophthalmological factors that could be helpful as biomarkers of the disease, potentially leading to an earlier prediction of disease course and disability progression.
Design:
Retrospective, cross-sectional-study.
Methods:
Best-corrected visual acuity (BCVA), ophthalmological biomicroscopy of the anterior segment and fundus, structural optical coherence tomography (OCT) with retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC), and OCT angiography (OCTA) with vascular density (VD) were performed. The following clinical and neuro-radiological features were assessed: MS phenotype, disease duration, clinical severity, type of treatment, and T2-weighted lesion and T1-weighted Gd+ enhancing lesion number on the brain and spinal cord MRI.
Results:
One hundred and six patients (212 eyes) were analyzed. Sixty-six of them (62.2%) had MS and 40 (37.8%) were matched healthy controls (HCs). patients with MS showed lower RNFL, GCC, and VD in the radial peripapillary capillary plexus than controls in both eyes (P < .05). By Performing a logistic regression with a distinct MS outcome for both eyes, we were able to demonstrate that the value that was most predictive of MS was the average GCC thickness (P = .009). Regression analysis demonstrated that patients with a higher T2-weighted lesions showed a lower RNFL thickness value and reduced GCC and VD values than those with a low lesion load (P < .01 and P < .05, respectively). Similarly, relapsing MS patients showed lower RNFL values (P < .05).
Conclusions:
Several OCT and OCTA-optic nerve parameters could be useful prognostic biomarkers for the MS disease course in clinical practice. However, it is necessary to do additional research with larger sample sizes in order to validate these findings.
More Related Videos
12:23Dynamic Visual Tests to Identify and Quantify Visual Damage and Repair Following Demyelination in Optic Neuritis Patients
Published on: April 14, 2014
07:08Using Optical Coherence Tomography and Optokinetic Response As Structural and Functional Visual System Readouts in Mice and Rats
Published on: January 10, 2019
Related Concept Videos
Glaucoma: Overview
Imaging Studies III: Computed Tomography
Multiple Sclerosis l: Introduction