Related Experiment Video
Updated: May 5, 2026

An Anesthesia, Surgery, and Harvest Method for the Evaluation of Transpedicular Screws Using an In Vivo Porcine Lumbar Spine Model
Published on: May 31, 2017
Biomechanical analysis of single and multi-level artificial disc replacement (ADR) in cervical spine using
Ram Kumar1, Amit Kumar1, Shabanam Kumari2
1Department of Mechanical Engineering, National Institute of Technology, Patna, Bihar, India.
Abstract:
Artificial disc replacement (ADR) is a clinical procedure used to diagnose cervical degenerative disc disease, preserving range of motion (ROM) at the fixation level and preventing adjacent segment degeneration (ASD). This study analyzed the biomechanics of ADR by examining range of motion (ROM), stress levels in bone and implants, and strain in the bone-implant interface using multi-scale loadings. The study focused on single- and double-level patients across various loading scales during physiological motions within the cervical spine. Results showed increased ROM in single-level and double-level fixations during physiological loadings, while ROM decreased at the adjacent level of fixation with the intact cervical spine model. The Prodisc-Implant metal endplate experienced a maximum von Mises stress of 432 MPa during axial rotation, confirming the long durability and biomechanical performance of the bone-implant interface.
Related Concept Videos
Herniated Intervertebral Disc l: Introduction
Degenerative Disc Disease I: Introduction
Degenerative Disc Disease ll: Pathophysiology