Related Experiment Video
Updated: May 10, 2026

Surgical Technique for the Implantation of Tissue Engineered Vascular Grafts and Subsequent In Vivo Monitoring
Published on: April 3, 2015
The evolution of TAVI performance overtime: an overview of systematic reviews
Carmen Angioletti1, Giaele Moretti2, Stefania Manetti3
1Management and Healthcare Laboratory, Institute of Management, Sant'Anna School of Advanced Studies, Pisa, Italy.
Background:
Transcatheter aortic valve implantation (TAVI) is a well-established treatment for high and intermediate-risk patients with severe aortic stenosis (AS). Recent studies have demonstrated non-inferiority of TAVI compared to surgery in low-risk patients. In the past decade, numerous literature reviews (SLRs) have assessed the use of TAVI in different risk groups. This is the first attempt to provide an overview of SRs (OoSRs) focusing on secondary studies reporting clinical outcomes/process indicators. This research aims to summarize the findings of extant literature on the performance of TAVI over time.
Methods:
A literature search took place from inception to April 2024. We searched MEDLINE and the Cochrane Library for SLRs. SLRs reporting at least one review of clinical indicators were included. Subsequently, a two-step inclusion process was conducted: [1] screening based on title and abstracts and [2] screening based on full-text papers. Relevant data were extracted and the quality of the reviews was assessed.
Results:
We included 33 SLRs with different risks assessed via the Society of Thoracic Surgeons (STS) score. Mortality rates were comparable between TAVI and Surgical Aortic Valve Replacement (SAVR) groups. TAVI is associated with lower rates of major bleeding, acute kidney injury (AKI) incidence, and new-onset atrial fibrillation. Vascular complications, pacemaker implantation, and residual aortic regurgitation were more frequent in TAVI patients.
Conclusion:
This study summarizes TAVI performance findings over a decade, revealing a shift to include both high and low-risk patients since 2020. Overall, TAVI continues to evolve, emphasizing improved outcomes, broader indications, and addressing challenges.
More Related Videos
Related Concept Videos
Transient and Steady-state Response
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
Time-Domain Interpretation of PD Control
Consider the example of control of motor torque. Initially, a positive...
Time and frequency -Domain Interpretation of Phase-lead Control
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
Instrument Transformers
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Interpreting Run Charts

