Related Experiment Video
Updated: Jun 23, 2025

Mechanical Expansion of Steel Tubing as a Solution to Leaky Wellbores
Published on: November 20, 2014
Sealing faults and fluid-induced seismicity
Zahra Esmaeilzadeh1, David W Eaton1, Navid Hosseini2
1Department of Earth, Energy & Environment, University of Calgary , Calgary, Alberta, Canada.
Abstract:
Sealing faults are nearly impermeable barriers that can form boundaries between subsurface pore-pressure domains. In hydrocarbon systems, sealing faults commonly form part of a structural trap; they are thus important elements for future storage of CO2 and other gases in depleted reservoirs. The Triassic Montney Formation in western Canada hosts low-permeability gas reservoirs containing sealing faults that have previously been assumed to compartmentalize pressure domains. In this study, we show that the distribution of induced seismicity associated with hydraulic fracturing (HF) exhibits a statistically significant spatial correlation with zones of high lateral gradient in pore pressure. These high-gradient zones are interpreted as sealing fault systems. The largest induced seismicity sequence, including a 4.5 ML mainshock on 30 November 2018, occurred during HF treatments in two horizontal wells, between which there is an exceptionally large contrast (~10 MPa) in measured pore pressure. Numerical simulation of a simplified model of a hydraulic fracture intersecting a nearby vertical fault, followed by fault rupture using rate-and-state friction rheology, generates results that are in good agreement with observed strike-slip faulting near one of the HF wells. Our study demonstrates that sealing faults exhibit previously unrecognized behaviour that may be important for understanding induced seismicity risk. This article is part of the theme issue 'Induced seismicity in coupled subsurface systems'.
Related Concept Videos
Types of Building Separation Joints
Volume-change joints address the effects of expansion and contraction due to temperature and moisture variations. They are strategically placed at discontinuities in a building's mass where cracking is most likely and are spaced about 150 to 200...
Microcracking in Concrete
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...
Plane Potential Flows
Uniform...
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Unsoundness of Aggregate due to Volume Change

