Calcium-Free Dialysate Hemodialysis: A Simplified Approach

Alexandra Corbu1, Florian Terrec1, Paolo Malvezzi1

  • 1Nephrology, Haemodialysis, Apheresis and Kidney Transplantation Department, Grenoble University Hospital, 38043 Grenoble, France.

Intermittent hemodialysis (HD) in high-bleeding-risk patients presents a challenge as circuit anticoagulation using heparin is contraindicated in such cases. Recently, the use of calcium-free citrate-containing dialysate with calcium supplementation emerged as a viable alternative to heparin-circuit anticoagulation. This is a retrospective, monocentric study to evaluate dialysis efficacy using calcium-free citrate-containing dialysate with calcium reinjection into the venous line in hemodialysis patients at risk of bleeding. A total of 53 patients were analyzed: 52 had a temporary contraindication to systemic anticoagulation (active bleeding or surgical intervention), and 1 chronic HD patient had prolonged bleeding time due to inoperable arteriovenous fistula stenosis. Only 7 out of 79 dialysis sessions performed were prematurely terminated (vascular access dysfunction). The median dialysis time was 240 min (range: 150-300). The chronic dialysis patient had 108 sessions with no premature termination. Frequent monitoring of ionized calcium was performed throughout the dialysis sessions: levels remained stable at T0 and T + 60 min (1.08 ± 0.08 mmol/L) and slightly increased at the end of the dialysis session (1.19 ± 0.13 mmol/L), remaining within normal limits. Target postfilter ionized calcium <0.4 mmol/L was achieved in all sessions (0.31 ± 0.07 mmol/L). There were no cases of symptomatic hypo-/hypercalcemia and no need for calcium infusion rate adjustment throughout the sessions. Hemodialysis with calcium-free citrate-containing dialysate and calcium reinjection into the venous line is efficient and safe in HD patients with contraindications to systemic anticoagulation.

Related Concept Videos

Dialysis01:15

Dialysis

Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
634
Formation of Dilute Urine01:20

Formation of Dilute Urine

The formation of dilute urine is a critical renal adaptation that maintains fluid balance, particularly during periods of high fluid intake. This process primarily involves the juxtamedullary nephrons. By adjusting the permeability of water and ions in response to physiological conditions, the kidneys can either conserve or excrete water, resulting in concentrated or dilute urine.
Filtrate Osmolarity in the PCT
Initially, as the filtrate passes through the proximal convoluted tubule (PCT), its...
1.5K
EDTA: Direct, Back-, and Displacement Titration01:30

EDTA: Direct, Back-, and Displacement Titration

The EDTA titration types for metal ion analysis include direct titration, back-titration, and replacement titration.
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
2.7K
Complexometric EDTA Titration Curves01:20

Complexometric EDTA Titration Curves

EDTA titration curves determine the free metal ion concentration. The titration curve represents the change in concentration of free metal ions (p function) as a function of the volume of EDTA added. This curve consists of three regions: before, at, and after equivalence points. Excess free metal ions are present before the equivalence point. Equal concentrations of metal ions and EDTA are present at the equivalence point. After the equivalence point, excess EDTA exists. This means slight...
842
Capillary Electrophoresis: Applications01:30

Capillary Electrophoresis: Applications

Capillary electrophoretic separations offer various modes, each with unique applications. These modes include capillary zone electrophoresis, capillary gel electrophoresis, capillary array electrophoresis, capillary isoelectric focusing, capillary isotachophoresis, micellar electrokinetic chromatography, and capillary electrochromatography.
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
373