Diagnostic Performance of FAPI PET/CT vs. 18F-FDG PET/CT in Evaluation of Liver Tumors: A Systematic Review and
Parneet Singh1, Tejasvini Singhal1, Girish Kumar Parida1
1All India Institute of Medical Sciences, Department of Nuclear Medicine, Bhubaneswar, India.
Objectives:
Primary liver tumors constitute one of the most common tumors. These are aggressive tumors with poor survival. Fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT), most commonly used functional imaging, shows limited tracer retention and poor tumor to background ratios (TBR). Novel 68Ga-fibroblast-activation-protein inhibitor (FAPI) PET/CT has shown better tracer uptake and detection efficacy in liver tumors. However, most of the available literature is limited to single center studies with limited number of patients. So, we tried to review and analyze the head-to-head comparison of 18F-FDG PET/CT and 68Ga-FAPI PET/CT in evaluation of liver tumors.
Methods:
Literature available on head to head comparison of diagnostic accuracy of 18F-FDG PET/CT and 68Ga-FAPI PET/CT was searched in databases like PubMed, SCOPUS, EMBASE and Google Scholar for published original studies till April 2023. The relevant studies were selected and assessed using the Revised Tool for the Quality Assessment of Diagnostic Accuracy Studies-2 checklist. A random-effect model was used for calculating pooled sensitivity and specificity. They were represented with 95% confidence intervals (95% CI) and demonstrated in Forest plots. I-square statistic was used to assess heterogeneity in the studies.
Results:
Pooled sensitivity and specificity of FAPI PET/CT and 18F-FDG PET/CT for detection of primary liver tumors was 94.3% (95% CI: 90.6-96.8%); 89.3% (95% CI: 71.8-97.7%) and 56.1% (95% CI: 49.7-62.5%); 96.4% (95% CI: 81.7-99.9%) respectively. Pooled sensitivity for detection of extrahepatic metastatic disease was 92.2% (range: 88.1-100%; 95% CI: 87.8-95.4%) and 72.4% (range: 69.8-76.5; 95% CI: 65.9-78.2%) respectively. Also, the maximum standardized uptake value (SUVmax) and TBR were higher for FAPI PET/CT than 18F-FDG PET/CT in the included studies.
Conclusion:
Overall, FAPI PET/CT showed higher sensitivity for detection of liver tumors with better SUVmax and TBR than 18F-FDG PET/CT.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

![An Automated Radiosynthesis of [68Ga]Ga-FAPI-46 for Routine Clinical Use](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F66708.jpg&w=3840&q=50)