Related Experiment Video
Updated: Jun 22, 2025

Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
An exploratory study of structural and microvascular changes in the skin following electrical shaving using optical
Pakhi Chaturvedi1,2, Wilco Kroon2, Giulia Zanelli2
1Skin Sensing Research Group, School of Health Sciences, University of Southampton, Southampton, UK.
Background:
Consumer products such as electrical shavers exert a combination of dynamic loading in the form of pressure and shear on the skin. This mechanical stimulus can lead to discomfort and skin tissue responses characterised as "Skin Sensitivity". To minimise discomfort following shaving, there is a need to establish specific stimulus-response relationships using advanced tools such as optical coherence tomography (OCT).
Objective:
To explore the spatial and temporal changes in skin morphology and microvascular function following an electrical shaving stimulus.
Methods:
Ten healthy male volunteers were recruited. The study included a 60-s electrical shaving stimulus on the forearm, cheek and neck. Skin parameters were recorded at baseline, 20 min post stimulus and 24 h post stimulus. Structural and dynamic skin parameters were estimated using OCT, while transepidermal water loss (TEWL) was recorded to provide reference values for skin barrier function.
Results:
At baseline, six of the eight parameters revealed statistically significant differences between the forearm and the facial sites, while only surface roughness (Rq) and reflectivity were statistically different (p < 0.05) between the cheek and neck. At 20 min post shaving, there was a significant increase in the TEWL values accompanied by increased blood perfusion, with varying magnitude of change dependent on the anatomical site. Recovery characteristics were observed 24 h post stimulus with most parameters returning to basal values, highlighting the transient influence of the stimulus.
Conclusions:
OCT parameters revealed spatial and temporal differences in the skin tissue response to electrical shaving. This approach could inform shaver design and prevent skin sensitivity.
More Related Videos
07:44In vivo Structural Assessments of Ocular Disease in Rodent Models using Optical Coherence Tomography
Published on: July 24, 2020
09:37Combining Reflectance Confocal Microscopy with Optical Coherence Tomography for Noninvasive Diagnosis of Skin Cancers via Image Acquisition
Published on: August 18, 2022