Related Experiment Video
Updated: Jun 22, 2025

Monitoring Lung Function with Electrical Impedance Tomography in the Intensive Care Unit
Published on: September 6, 2024
Incremental Application of Positive End-Expiratory Pressure for the Evaluation of Atelectasis During RP-EBUS and
Grant D Senyei1,2, Ala Eddin S Sagar3, Brian Tran4
1Division of Pulmonary, Critical Care, and Sleep Medicine, University of California San Diego, La Jolla, CA.
Background:
CT-to-body divergence-described as the difference between preprocedural CT scans and intraprocedural lung architecture-is a significant barrier to improving diagnostic yield during navigational bronchoscopy. A major proposed contributor to CT-to-body divergence is the development of atelectasis, which can confound visualization of peripheral lung lesions via radial probe endobronchial ultrasound (RP-EBUS). High positive end-expiratory pressure (PEEP) ventilatory strategies have been used to decrease atelectasis, allowing the lesion to re-APPEAR on intraprocedure imaging. However, standardized PEEP levels may not be appropriate for all patients due to hemodynamic and ventilatory impacts.
Methods:
We performed a multicenter, prospective observational study in which patients were imaged with RP-EBUS under general anesthesia to determine if subsegmental atelectasis would resolve as incremental increases in PEEP were applied. Resolution of atelectasis was based on the transition from a non-aerated pattern to an aerated appearance on RP-EBUS. RP-EBUS images were reviewed by 3 experienced operators to determine correlation.
Results:
Forty-three patients underwent RP-EBUS examination following navigational bronchoscopy. Thirty-seven patients underwent incremental PEEP application and subsequent RP-EBUS imaging. Atelectasis was determined to have resolved in 33 patients (88.2%) following increased PEEP. The intraclass correlation coefficient between reviewers was 0.76. A recruitment maneuver was performed in 7 (16.3%) patients after atelectasis persisted at maximal PEEP. Atelectasis was not identified in the examined subsegments in 6 (10.8%) patients despite zero PEEP.
Conclusion:
RP-EBUS is an effective tool to monitor what pressure atelectasis within a lung segment has resolved with increasing levels of PEEP.
Related Concept Videos
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation I: Indication and Settings
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...

