Related Experiment Video
Updated: Jun 22, 2025

An Ivor Lewis Esophagectomy Designed to Minimize Anastomotic Complications and Optimize Conduit Function
Published on: April 17, 2020
Impact of Circular Stapler Size on the Risk of Anastomotic Complications in Patients With Left-sided Colorectal
Masatsune Shibutani1, Tatsunari Fukuoka1, Yasuhito Iseki1
1Department of Gastroenterological Surgery, Osaka Metropolitan University Graduate School of Medicine, Osaka, Japan.
Background/Aim:
The present study examined the impact of circular stapler size on anastomotic complications, including leakage and stricture in patients undergoing double-stapling technique (DST) anastomosis for left-sided colon or rectal cancer.
Patients And Methods:
A total of 403 patients were enrolled in this study, with circular stapler sizes of 25, 28, and 29 mm.
Results:
A small circular stapler (25 mm) was used in 170 cases (42.2%), and a medium-sized circular stapler (28/29 mm) was used in 233 cases (57.8%). After propensity score matching, there was no marked difference in the incidence of anastomotic leakage/stricture between the groups (13.9% vs. 10.9%, 3.0% vs. 1.0%, respectively).
Conclusion:
The size of the circular stapler was not associated with the incidence of anastomotic leakage or stricture in this cohort.
More Related Videos
07:51The C-seal: A Biofragmentable Drain Protecting the Stapled Colorectal Anastomosis from Leakage
Published on: November 4, 2010
08:26Clinical Application of Single-Surgeon, Three-Port, Laparoscopic Resection for Colorectal Cancer with Natural Orifice Specimen Extraction
Published on: March 24, 2023
Related Concept Videos
Inflammatory Bowel Disease V: Surgical Management
Here are some common surgical interventions for IBD:
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...