Background:
Neurological disorders arise primarily from the dysfunction of brain cells, leading to various impairments. Electroencephalography (EEG) stands out as the most popular method in the discovery of neuromarkers indicating neurological disorders. The proposed study investigates the effectiveness of spectral and synchrony neuromarkers derived from resting state EEG in the detection of Mild Cognitive Impairment (MCI) with controls.
New Methods:
The dataset is composed of 10 MCI and 10 HC groups. Spectral features and synchrony measures are utilized to detect slowing patterns in MCI. Efficient neuro-markers are classified by 25 classification algorithm. Independent samples t-test and Pearson's Correlation Coefficients are applied to reveal group differences for spectral markers, and repeated measures ANOVA is tested for wPLI-based markers.
Results:
Lower peak amplitudes are prominent in MCI participants for high frequencies indicating slower physiological behavior of the demented EEG. The MCI and HC groups are correctly classified with 95 % acc. using peak amplitudes of beta band with LGBM classifier. Higher wPLI values are calculated for HC participants in high frequencies. The alpha wPLI values achieve a classification accuracy of 99 % using the LGBM algorithm for MCI detection.
Comparison With Existing Methods:
The neuro-markers including peak amplitudes, frequencies, and wPLIs with advanced machine learning techniques showcases the innovative nature of this research.
Conclusion: