Measurement of 224Ra in water via pulsed ionization chamber (PIC) radon detector
Haowei Xu1, Chunqian Li2, Pengxia Liu3
1Frontiers Science Center for Deep Ocean Multispheres and Earth System, and Key Laboratory of Marine Chemistry Theory and Technology, Ministry of Education, Ocean University of China, Qingdao, 266100, China; Laboratory for Marine Ecology and Environmental Science, Qingdao National Laboratory for Marine Science and Technology, Qingdao, 266071, China; College of Chemistry and Chemical Engineering, Ocean University of China, Qingdao, 266100, China.
Abstract:
224Ra (t1/2 = 3.6 d) has been widely used as a tracer in environmental water research. Here, we present a new method for measuring 224Ra in natural waters using a pulsed ionization chamber (PIC)-based radon detector. This method is based on the measurement of the 224Ra daughter isotope 220Rn (thoron) after reaching secular equilibrium within 7 min. Radium isotopes are concentrated on ''Mn-fibers'' before measurement of 220Rn, which can be distinguished from 222Rn by the difference in their half-lives. The measurement efficiency of the method is 0.20 ± 0.01 cps/Bq at an optimum airflow rate of 1.0 L/min and a water/Mn-fiber weight ratio of 1.0. Results from natural water samples obtained by this method agree well with analysis via RaDeCC, an established technique for 224Ra assessments. Since the PIC system is lighter compared to RaDeCC, easier to operate, and does not require the usage of helium carrier gas and desiccant, this method is recommended for in-situ 224Ra measurement in long-term fieldwork with limited logistical support.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Biological Effects of Radiation
Gas Chromatography: Types of Detectors-II
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Radiation and Light Sources
Two common narrow-range 'line' sources used in AAS are hollow-cathode lamps (HCLs) and...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...