A feasibility study of sample re-collection in the analysis of selected volatile compounds in breath samples using
Nina Nouri1, Ning Sun2, Jane E Hill3
1Department of Chemical and Biological Engineering, University of British Columbia, Vancouver, BC, Canada.
Abstract:
In this study, we aimed to assess the feasibility of re-collecting breath samples using the Centri® (Markes International, Bridgend, UK) followed by two-dimensional gas chromatography coupled with time-of-flight mass spectrometry (GC×GC-TOFMS) analysis. The work was conducted in two main phases. In the first phase, we evaluated the re-collection performance by analyzing two sets of standards, including a Grob mix primary solution and a standard mixture of 20 selected volatile compounds (VCs) covering different classes of organic species commonly found in breath samples. The intra-day and inter-day precision (reported as relative standard deviation (RSD),%) for the re-collection of the Grob mix primary solution were in the range of 1 % to14 % and 3 % to12 %, respectively. The re-collection accuracy ranged from 78 % to 97 %. The intra-day RSD for the re-collection of the standard mixture of selected VCs was within 20 % for all compounds, except for acetone and nonane. The precision was within 25 % for all compounds, except for nonane, n-hexane, 1,4-dichlorobenzene, and decane, which exhibited less than 36 % RSD. The re-collection accuracy was in the range of 67 % to 129 %. In the second phase of the study, the re-collection performance in breath analysis was evaluated via five repetitive splitting and re-collection of six breath samples obtained from healthy adults, realizing a total of 30 breath analyses. Initially, we evaluated the re-collection performance by considering all features obtained from breath analysis and then focused on the 20 VCs commonly found in breath samples. The re-collection accuracy for total breath features ranged from 86 to 103 %, and the RSDs were in the range of 1.0 % to 10.4 %. For the selected VCs, the re-collection accuracy of all compounds, except for undecane and benzene, was in the range of 71 % to 132 %.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Sample Preparation for Analysis: Overview
Bulk or large solid samples are typically reduced in size using grinding, crushing, or milling techniques to increase the...
Volatilization
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...