Related Experiment Video
Updated: May 3, 2026

PET and MRI Guided Irradiation of a Glioblastoma Rat Model Using a Micro-irradiator
Published on: December 28, 2017
Assessing inter and intrafraction uncertainties in adult brain cancer patients using 2D/3D kV and CBCT imaging
K Indramohan1, S Moinuddin1, T Akter1
1Department of Radiotherapy UCLH, UK.
Method:
2D/3D kV imaging and CBCT data using 6 degrees of freedom (6DoF) were compared to evaluate inter and intrafraction motion.
Results:
Results showed that intrafraction errors were low and interfraction levels were within institutional protocols.
Conclusion:
Confidence was given to use low dose 2D/3D kV imaging to confirm daily patient set up errors, and to use pre-treatment CBCT only once weekly for additional imaging information.
Implications For Practice:
Further research is necessary to assess other uncertainties, to enable the calculation of a margin and determining the feasibility of further reduction of this.