The reliability and minimal detectable change of common tests and measures for temporomandibular disorders
Ovidio Olivencia1, Kelby B Kaplan1,2, Ashley Graham1
1Department of Physical Therapy, Nova Southeastern University, Fort Lauderdale, USA.
Background:
Temporomandibular disorders are a source of orofacial pain. Understanding clinimetric properties of evaluation procedures is necessary for assessing impairments and determining response to interventions.
Purpose:
Reliability, minimal detectable change (MDC95), and 95% limits of agreement of TMJ examination procedures were investigated.
Methods:
Occlusion (central incisor alignment, overjet, overbite), mandibular dynamics (maximal incisor opening, laterotrusion, protrusion active range of motion (AROM)), auscultation, tenderness, and joint play were measured on 50 asymptomatic adults (30 females), mean age 24.8. The inter-rater reliability assessment used an intra-session design. Participants returned 24-48 h later for intra-rater assessments. Intraclass correlation coefficients (ICC) and Kappa values were used to determine reproducibility.
Results:
Intra-rater reliability for occlusion and AROM was ICC 3,1 ≥ 0.75, whereas interrater reliability was ICC 2,1 ≥ 0.68. Kappa values for inter-rater agreement of joint mobility was K = .18, whereas auscultation and palpation were K ≥ 0.48. Intra-rater Kappa values were ≥ 0.24, with lateral pterygoid region palpation having poor agreement. The MDC95 for occlusion was 1 mm, whereas AROM ranged from 3 to 6 mm. Mean AROM differences between raters were -1.16, -0.42, -0.18, and -0.8 mm for maximal incisor opening, left and right laterotrusion, and protrusion, respectively.
Conclusion:
AROM and occlusion measurements may be used with confidence; however, poor agreement for joint mobility measurements and lateral pterygoid region palpation must be recognized. When re-assessing measurements, a 3-6 and 1-mm change in AROM and occlusion, respectively, is required to be 95% certain change is not due to error. Future symptomatic population research is needed (250/250).
More Related Videos
Related Concept Videos
Reliability and Validity
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Statistical Analysis: Overview
One of the most commonly used statistical quantifiers is the mean, which is the ratio between the sum of the numerical values of all results and the...
Central Tendency: Analysis
The mean is one such measure, calculated by totaling all values in a dataset and dividing by the number of values. For instance, the mean blood pressure reading (120, 130, 140, 150) would be 135. However, the mean can be affected by extreme values or outliers.
The median, another measure,...
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...