Research on methods to increase the flashover voltage of supporting insulators in Tesla transformers
Junna Li1, Haoliang Shi1, Yongliang Wang1
1State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710024, People's Republic of China.
Abstract:
This paper presents three methods aimed at enhancing the flashover voltage of the supporting insulator in a Tesla transformer. These methods include optimizing the maximum electric field on the insulator surface, adjusting the overall structure of the insulator, and changing the surface structure of the insulator. Ten insulator samples with different structures were designed based on electric field simulation. Subsequent experiments were conducted to validate the effectiveness of these methods in improving flashover voltage. On this basis, the supporting insulator of the Tesla transformer was redesigned, leading to an increased output voltage. The results are summarized in the following. First, optimization of the shielding rings of the cathode and anode reduces the electric field at the triple junction, which significantly increases the flashover voltage. Second, extending the inclination starting position of insulators with the same inclination angle effectively reduces the surface electric field intensity and increases the flashover voltage. Third, increasing the inclination angle within a certain range while keeping the inclination starting position constant extends the creepage distance and enhances the flashover voltage. However, excessively large inclination angles may lead to a decrease in flashover voltage due to excessive normal electric field. Fourth, grooving on the insulator surface at appropriate locations can inhibit the development of the streamer and improve flashover voltage. Finally, the supporting insulator of the Tesla transformer was redesigned based on these results, elevating the output voltage from 750 kV to over 1 MV.
Related Concept Videos
Insulation Coordination
Transformers in Distribution System
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...
Transmission Line Design Considerations
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
Transformers
The iron core has a substantial relative permeability. Therefore, the magnetic field lines generated due to the current in one winding are almost entirely confined within the core, such that the same magnetic flux permeates each turn of both...