Transducer Variability in Speech-in-Noise Testing: Considerations Related to Stimulus Bandwidth
Douglas S Brungart1, Alyssa J Davidson1
1National Military Audiology and Speech Center, Walter Reed National Military Medical Center, Bethesda, MD.
Purpose:
Clinical audiologists typically assume that headphones and insert phones will produce comparable results when they are used to conduct speech-in-noise or other audiological tests; however, this may not always be the case. Here, we show that there are significant differences in the scores that previous studies have reported for headphone and insert-phone transducers on the Words-in-Noise (WIN) Test, and discuss the possibility that the variations in high-frequency output that are allowable under the speech source specifications of American National Standards Institute S3.6 might be contributing to transducer-dependent differences in performance for the WIN and other tests that are presented through the auxiliary input channels of clinical audiometers.
Method:
A literature review was conducted to identify articles that reported WIN Test results for both listeners with normal hearing and with hearing impairment and specified the type of transducer (insert or TDH-50) used for the data collection.
Results:
Among the 19 included studies, participants with normal hearing using inserts exhibited systematically worse WIN Test scores compared to those using TDH-50 headphones, while participants with hearing loss showed comparable average scores across transducer types.
Conclusions:
The results highlight the importance of considering transducer type when interpreting WIN Test outcomes, particularly when comparing to normative scores obtained from individuals with normal hearing. Although further research is needed to elucidate the underlying mechanisms driving differences in test performance across transducer types, these findings underscore the need for standardized test administration protocols and careful documentation of transducer type when administering speech-in-noise tests for clinical or research applications.
More Related Videos
09:13Testing Sensory and Multisensory Function in Children with Autism Spectrum Disorder
Published on: April 22, 2015
14:05Behavioral Assessment of Hearing in 2 to 4 Year-old Children: A Two-interval, Observer-based Procedure Using Conditioned Play-based Responses
Published on: January 23, 2017
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and hence a...
Intensity and Pressure of Sound Waves
Unlike the time average of a sinusoidal term, which is zero since it is positive and...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Perceiving Loudness, Pitch, and Location
Place theory, or place coding, suggests that different pitches are heard because various sound waves activate specific locations along the cochlea's basilar membrane. The brain determines the pitch of a sound by identifying...