Utility of Second-look Ultrasonography in Distinguishing BI-RADS 4 Calcifications Detected on Mammography: An
Sheng Cheng1, Lin Zhu1, Ning Lin1
1Department of Ultrasonography, Shengli Clinical Medical College of Fujian Medical University, Fujian Provincial Hospital, Fuzhou University Affiliated Provincial Hospital, Fuzhou, Fujian Province, China.
Abstract:
This study aimed to assess the utility of second-look ultrasonography (US) in differentiating breast imaging reporting and data system (BI-RADS) 4 calcifications initially detected on mammography (MG). BI-RADS 4 calcifications have a wide range of positive predictive values. We hypothesized that second-look US would help distinguish BI-RADS 4 calcifications without clinical manifestations and other abnormalities on MG. This study included 1622 pure BI-RADS 4 calcifications in 1510 women (112 patients with bilateral calcifications). The cases were randomly divided into training (85%) and testing (15%) datasets. Two nomograms were developed to differentiate BI-RADS 4 calcifications in the training dataset: the MG-US nomogram, based on multifactorial logistic regression and incorporated clinical information, MG, and second-look US characteristics, and the MG nomogram, based on clinical information and mammographic characteristics. Calibration of the MG-US nomogram was performed using calibration curves. The discriminative ability and clinical utility of both nomograms were compared using the area under the receiver operating characteristic curve (AUC) and the decision analysis curve (DCA) in the test dataset. The clinical information and imaging characteristics were comparable between the training and test datasets. The bias-corrected calibration curves of the MG-US nomogram closely approximate the ideal line for both datasets. In the test dataset, the MG-US nomogram exhibited a higher AUC than the MG nomogram (0.899 vs 0.852, P = .01). DCA demonstrated the superiority of the MG-US nomogram over the MG nomogram. Second-look US features, including ultrasonic calcifications, lesions, and moderate or marked color flow, were valuable for distinguishing BI-RADS 4 calcifications without clinical manifestations and other abnormalities on MG.
Related Concept Videos
Ultrasonography
During an ultrasonography procedure, a handheld device called...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
X-ray Imaging