Recommendations for evaluating photoplethysmography-based algorithms for blood pressure assessment
Mohamed Elgendi1, Fridolin Haugg2, Richard Ribon Fletcher3
1Biomedical and Mobile Health Technology Lab, Department of Health Sciences and Technology, ETH Zurich, Zurich, 8008, Switzerland. moe.elgendi@hest.ethz.ch.
Photoplethysmography (PPG) algorithms for blood pressure (BP) estimation have accuracy issues. Standardizing error evaluation in PPG algorithm development is recommended to improve BP measurement reliability for hypertension management.
Area of Science:
- Biomedical Engineering
- Medical Devices
- Physiological Monitoring
Background:
- Photoplethysmography (PPG) is a non-invasive optical method for assessing blood volume changes.
- PPG shows promise for clinical blood pressure (BP) assessment and hypertension management.
- PPG-based algorithms can introduce bias and inaccuracy, impacting performance.
Purpose of the Study:
- To review existing measures for assessing PPG-based algorithm performance.
- To recommend standardized error evaluation in PPG algorithm development.
- To enhance the reliability and accuracy of PPG-based BP estimation.
Main Methods:
- Review of seven widely used measures for PPG-based algorithm performance evaluation.
- Analysis of sources of error affecting PPG measurements.
- Recommendation for standardized development and validation protocols.
Main Results:
- Identification of key error sources in PPG-based BP algorithms.
- Evaluation of current performance assessment measures.
- Highlighting the need for standardized error analysis.
Conclusions:
- Standardized error evaluation in PPG algorithm development is crucial.
- Improved accuracy in PPG-based BP estimation can enhance hypertension management.
- Reliable PPG technology can lead to better patient health outcomes.
More Related Videos
Related Concept Videos
Pre-Procedural Guidelines for Assessing Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure: