GC × GC-HRMS with complementary ionization methods in the suspect screening analysis of fragrance allergens:
Dmitrii M Mazur1, Vyacheslav B Artaev2, Albert T Lebedev3
1Department of Materials Science, MSU-BIT University, Shenzhen, 517182, China.
Abstract:
Modern gas chromatography-mass spectrometry (GC-MS) allows for the analysis of complex samples, such as fragrances. However, identifying all the constituents in natural fragrance mixtures, especially allergens that need to be listed on product labels, is a significant challenge. This is primarily due to the high complexity of the sample and the fact that electron ionization, the most commonly used ionization method in GC-MS, produces numerous nonspecific fragment ions, often resulting in the absence or very low abundance of the molecular ion. These factors affect confidence in assigning the analyte. In this study, we demonstrate that the combination of GC × GC separation, with high mass resolution and accurate mass measurements, as well as chemical ionization in addition to traditional electron ionization, becomes an efficient tool for reliable qualitative analysis of a mixture containing 100 fragrance allergens, even when many of them are closely related species or isomers. The proposed approach expands the applicability of the comprehensive GC × GC-HRMS method, which includes complementary ionization techniques, from studies on anthropogenic priority pollutants and emerging contaminants to the analysis of natural products. Although targeted qualitative and quantitative analysis of allergens in the modern laboratories is well organized, GC × GC-HRMS, being a useful complement to routine quality control of volatile allergens in fragrances, definitely gives an additional contribution to the analytical cases when conventional 1D-GC-MS faces some problems or uncertainties.
More Related Videos
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-II
High-Resolution Mass Spectrometry (HRMS)
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
High-Performance Liquid Chromatography: Types of Detectors