Detecting localized damage in cantilevered structures under nonstationary ambient excitations via Gabor spectral mode
HongJie Zhang1, Qigang Sun2, DanYu Li1
1Power Transmission and Transformation Engineering Department, China Electric Power Research Institute, Beijing, 100192, China.
Abstract:
A method based on Gabor spectral mode transmissibility functions (GSMTFs) is proposed to detect local damage in a cantilevered structure under nonstationary ambient excitations. Gabor transformation and singular value decomposition are used to reduce the influences of other vibration modes on Gabor spectral mode transmissibility functions and process nonstationary structural responses, respectively. A new state characteristic based on the fundamental structure frequency is formulated on the basis of the GSMTFs, eventually leading to the development of a new damage indicator. The probability density functions of the damage indicator for healthy and damaged states can be estimated from the measured data, and the receiver operating characteristic (ROC) curve derived from these probability distributions and the corresponding area under the ROC curve (AUC) are used to determine the damage location. A six-degree-of-freedom system and a typical transmission tower are numerically studied, and the results show that the proposed method can estimate the structural damage location under nonstationary random loads. The proposed method is further validated with a planar frame in the laboratory, which exhibits multiple damage elements via random force hammer excitations. The results show that the AUC values computed for certain parts of the structure containing the damaged elements are greater than those for other parts of the structure, indicating the effectiveness of the proposed method. Moreover, the proposed method is compared with the dot product difference (DPD) index, and the results from the laboratory planar frame demonstrate that the proposed method can better identify damage.
Related Concept Videos
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Beams with Symmetric Loadings
The M/EI...
Modes of Standing Waves - I
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...