Optical fiber sensor for wearable and accurate human respiratory monitoring
Min Shao1, Yubo Yuan1, Manyin Wang1
1School of Science, Ministry of Education Key Laboratory on Photoelectric Oil-gas Logging and Detecting, Xi'an Shiyou University , Xi'an 710065, China.
Abstract:
Accurate respiratory monitoring is of great significance in assessing and analyzing physical health, and preventing respiratory diseases. The recently emerged wearable respiratory sensors are confronted with the challenges such as complex fabrication processes, limited accuracy, and stringent wearing requirements. An optical fiber sensor for accurate human respiratory monitoring is proposed and experimentally verified. The sensor head is composed of a piece of seven core fiber sandwiched between two single-mode fibers by two fiber bitapers, which is embedded in a textile sheet and freely worn on the upper body. An efficient signal demodulation system is set up to acquire the respiratory signal, while Fourier transform (FFT) and short-time Fourier transform (STFT) methods are used to analyze the measured signal. Six volunteers are invited to perform the respiratory experiment, and the experimental results demonstrate that the sensor can accurately detect and distinguish respiratory signals under different humans, different states (normal, slow, fast), different body parts (abdomen, chest, back), different postures (standing, sitting, lying), and irregular respiration. The Pearson correlation coefficient of the sensor is higher than 0.9, which is consistent with commercial respiratory sensor. Meanwhile, the instability of the sensor is 0.003 Hz for the same volunteer in 6 months. The sensor has the advantages of high sensitivity, good stability and wearing comfort, showing good potential in healthcare applications.
More Related Videos
08:21Wideband Optical Detector of Ultrasound for Medical Imaging Applications
Published on: May 11, 2014
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Respiratory Assessment: Purpose and Indications
Objectives and Importance:
The primary goal of respiratory assessment is to evaluate patients at early risk of clinical deterioration. Since respiratory distress often precedes other signs of declining health, breathing patterns and sounds become a...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...