The effect of irrigation solution temperature and novel heat-treated rotary files on apical debris extrusion and canal preparation time
Related Experiment Video
Updated: May 8, 2026

Oral Biofilm Analysis of Palatal Expanders by Fluorescence In-Situ Hybridization and Confocal Laser Scanning Microscopy
Published on: October 20, 2011
Taher Al Omari1, Amre R Atmeh2, Fahda N Algahtani3
1Department of Conservative Dentistry, Faculty of Dentistry, Jordan University of Science and Technology, Irbid, Jordan.
Abstract:
This study aimed to compare apical debris extrusion and canal preparation time with ProTaper Gold (PTG) and ProTaper Ultimate (PTU) files at different temperatures. Mesio-buccal roots of 60 mandibular first molars were distributed into six groups depending on the file type (PTG, PTU) and irrigation solution temperature (20, 37, 45°C). During instrumentation, extruded debris were collected and weighed to measure the mass in milligrams. The canal preparation time was recorded in seconds. ANOVA followed by Bonferroni post-hoc tests were used for analysis. The amount of debris extrusion was significantly higher in PTU, which was affected by the irrigation solution temperature (p < 0.05). The difference in canal preparation time was not significant between the two file systems, however, it was significant between the different temperatures (p = 0.001). Both file systems had shorter canal preparation times at 20°C. The irrigation solution temperature could influence the debris extrusion and time of canal preparation.