Introduction:
Management of infection on internal fixation hardware is particularly complex. The main aim of the present study was to assess bone consolidation rates under septic conditions in patients treated for bone and joint infection (BJI) with hardware retention. Secondary objectives were to determine a time limit beyond which it is unreasonable to retain hardware, and to assess risk factors for non-consolidation and functional results. The study hypothesis was that bone consolidation is possible under septic conditions without hardware exchange.
Material And Method:
A single-center retrospective observational study was conducted on 69 patients for the period January 1, 2009 to December 31, 2019. We included all patients aged over 15 years with infection after internal fixation or fusion whose files had been discussed in the multidisciplinary team meeting during the study period. Bone healing was screened for on X-ray or CT. Study data comprised type of fracture, smoking status, time to treatment for open fracture, initial surgery time, type of hardware, interval between fixation and revision, and type of irrigation. Functional results were assessed at follow-up: walking, pain, return to work and SF12 and QuickDASH scores.
Results:
The bone healing rate was 73.5% (50/68 patients) at a mean 24 weeks (range, 6-68 weeks). Time to revision did not significantly impact consolidation: 60% for 2 weeks (6/10 cases), 80% for 2-10 weeks (35/40 cases), and 64% for >10 weeks (9/14 cases) (p = 0.28). Smoking, longer initial surgery time and Gustilo type IIIb or IIIc were significant risks factors for non-consolidation.
Discussion:
Bone consolidation under septic conditions with hardware retention adhering to an established medical and surgical protocol was reliable and straightforward, without extra morbidity. These findings are encouraging, and in line with the literature. We were unable to determine a time limit beyond which hardware prevented healing.
Level Of Evidence:
IV; descriptive epidemiological study.
Related Concept Videos
What is the Skeletal System?
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Tissue Transplantation
The Biology of Tissue Transplantation
The biology of tissue transplantation hinges on the Major Histocompatibility Complex (MHC) molecules. These molecules...