Related Experiment Video
Updated: Jun 20, 2025

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
End-tidal carbon dioxide during spontaneous breathing trial to predict extubation failure: A prospective
Faten May1, Nicolas de Prost1, Keyvan Razazi1
1AP-HP, Hôpitaux Universitaires Henri-Mondor, Service de Médecine Intensive Réanimation, F-94010 Créteil, France; Univ Paris Est Créteil, CARMAS, Créteil F-94010, France; Univ Paris Est Créteil, INSERM, IMRB, Créteil F-94010, France.
None:
Despite advances in weaning protocols, extubation failure (EF) is associated with poor outcomes. Many predictors of EF have been proposed, including hypercapnia at the end of the spontaneous breathing test (SBT). However, performing arterial blood gases at the end of SBT is not routinely recommended, whereas end-tidal carbon dioxide (EtCO2) can be routinely monitored during SBT. We aimed to evaluate the clinical utility of EtCO2 to predict EF. Patients undergoing planned extubation were eligible. Non-inclusion criteria were tracheostomy and patients extubated after successful T-tube SBT. We recorded clinical data and EtCO2 in 189 patients during a successful one-hour low pressure support SBT. EtCO2 measured before successful SBT was lower in patients with EF compared to those with successful extubation (27 [24-29] vs 30 [27-47] mmHg, p = 0.02), while EtCO2 measured at five minutes and at the end of the SBT was not different between the two groups (26 [22-28] vs. 29 [28-49] mmHg, p = 0.06 and 26 [26-29] vs. 29 [27-49] mmHg, p = 0.09, respectively). Variables identified by multivariable analysis as independently associated with EF were acute respiratory failure as the cause of intubation and ineffective cough. Our study suggests that recording EtCO2 during successful SBT appears to have limited predictive value for EF.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Acute Respiratory Failure-III
Acute Respiratory Failure-I
Definition: It is defined by specific criteria based on blood gas measurements. Hypoxemia happens when the partial pressure of oxygen (PaO2) falls below 60 mmHg. At the same time,...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Acute Respiratory Failure-IV