Related Experiment Video
Updated: Jul 15, 2026
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)
Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury
Published on: November 9, 2018
Feasibility of direct brain 18F-fluorodeoxyglucose-positron emission tomography attenuation and high-resolution
Tomohiro Ueda1, Kosuke Yamashita1, Retsu Kawazoe1
1Graduate School of Health Sciences, Kumamoto University, Japan.
Objectives:
To develop the following three attenuation correction (AC) methods for brain 18F-fluorodeoxyglucose-positron emission tomography (PET), using deep learning, and to ascertain their precision levels: (i) indirect method; (ii) direct method; and (iii) direct and high-resolution correction (direct+HRC) method.
Methods:
We included 53 patients who underwent cranial magnetic resonance imaging (MRI) and computed tomography (CT) and 27 patients who underwent cranial MRI, CT, and PET. After fusion of the magnetic resonance, CT, and PET images, resampling was performed to standardize the field of view and matrix size and prepare the data set. In the indirect method, synthetic CT (SCT) images were generated, whereas in the direct and direct+HRC methods, a U-net structure was used to generate AC images. In the indirect method, attenuation correction was performed using SCT images generated from MRI findings using U-net instead of CT images. In the direct and direct+HRC methods, AC images were generated directly from non-AC images using U-net, followed by image evaluation. The precision levels of AC images generated using the indirect and direct methods were compared based on the normalized mean squared error (NMSE) and structural similarity (SSIM).
Results:
Visual inspection revealed no difference between the AC images prepared using CT-based attenuation correction and those prepared using the three methods. The NMSE increased in the order indirect, direct, and direct+HRC methods, with values of 0.281×10-3, 4.62×10-3, and 12.7×10-3, respectively. Moreover, the SSIM of the direct+HRC method was 0.975.
Conclusion:
The direct+HRC method enables accurate attenuation without CT exposure and high-resolution correction without dedicated correction programs.
More Related Videos
09:03Radiotracer Administration for High Temporal Resolution Positron Emission Tomography of the Human Brain: Application to FDG-fPET
Published on: October 22, 2019
07:28Studying Metabolic Brain Connectivity Using 2-Deoxy-2-[18F]Fluoro-D-Glucose Dynamic Positron Emission Tomography at the Single-subject Level
Published on: January 24, 2025