Stroke Evaluation in the Interventional Suite Using Dual-Layer Detector Cone-Beam CT: a First-in-human Prospective
Fredrik Ståhl1,2, Håkan Almqvist3,4, Åsa Aspelin3
1Department of Neuroradiology, Karolinska University Hospital, Eugeniavägen 3, Stockholm, Sweden. Fredrik.stahl@regionstockholm.se.
Dual-layer cone-beam CT demonstrated non-inferior accuracy for detecting hemorrhages and assessing stroke severity (ASPECTS) compared to standard CT. While image quality was lower, this technique shows promise for interventional suite stroke evaluations.
Area of Science:
- Neuroradiology
- Medical Imaging
- Stroke Management
Background:
- Cone-beam CT (CBCT) in interventional suites offers potential to reduce door-to-thrombectomy times.
- Limitations of CBCT include artifacts and poor gray-white matter differentiation, impacting diagnostic accuracy.
- This study evaluated dual-layer CBCT as an alternative to conventional CT for acute stroke imaging.
Purpose of the Study:
- To compare the diagnostic performance of non-contrast brain dual-layer CBCT with standard CT in stroke patients.
- To assess hemorrhage detection accuracy and ASPECTS scoring using dual-layer CBCT.
- To evaluate subjective and objective image quality differences between dual-layer CBCT and CT.
Main Methods:
- Prospective single-center study of consecutive stroke patients (ischemic or hemorrhagic).
- Neuroradiologists assessed hemorrhage detection and ASPECTS accuracy on dual-layer CBCT (75 keV monoenergetic images) versus CT.
- Subjective image quality (Likert scales) and objective metrics were analyzed; non-inferiority was statistically determined.
Main Results:
- 27 participants included in the hyperacute/acute stroke phase.
- Majority analysis confirmed 100% hemorrhage detection accuracy (lower CI 86%) and 90% ASPECTS accuracy (lower CI 85%).
- Sensitivity for hemorrhage detection was 66%, specificity 97%; however, subjective and objective image quality were inferior to CT.
Conclusions:
- Dual-layer CBCT demonstrated non-inferior accuracy for hemorrhage detection and ASPECTS scoring compared to CT in a small cohort.
- Despite lower image quality, dual-layer CBCT may be a viable tool for stroke evaluation within the interventional suite.
- Further research is warranted to optimize CBCT protocols for stroke imaging.
More Related Videos
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
06:59Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Radiological Investigation I: X-ray and CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography