An Azaryl-Ketone-Based Thermally Activated Delayed Fluorophore with Aggregation-Induced Emission for Efficient

Wen-Cheng Chen1,2, Yaozu Su1,2, Xiaohui Wu1,2

  • 1Guangdong Provincial Laboratory of Chemistry and Fine Chemical Engineering Jieyang Center, Jieyang, 515200, People's Republic of China.

PubMed

Related Concept Videos

Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the...
2.9K
Variables Affecting Phosphorescence and Fluorescence01:26

Variables Affecting Phosphorescence and Fluorescence

Fluorescence and phosphorescence are essential phenomena in fields like analytical chemistry, biological imaging, and materials science, where they detect molecular properties and visualize cellular structures. Understanding the variables that influence these luminescent behaviors is crucial for maximizing accuracy and efficiency in their applications. These variables can broadly be grouped into chemical structure, solvent properties, and external conditions, each playing a distinct role in...
493
Cycloaddition Reactions: MO Requirements for Photochemical Activation01:12

Cycloaddition Reactions: MO Requirements for Photochemical Activation

Some cycloaddition reactions are activated by heat, while others are initiated by light. For example, a [2 + 2] cycloaddition between two ethylene molecules occurs only in the presence of light. It is photochemically allowed but thermally forbidden.
2.1K
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
385