Related Experiment Video
Updated: Jun 18, 2025

Extraction of the EPP Component from the Surface EMG
Published on: December 16, 2009
Band-Stop Frequency-Selective Surface (FSS) with Elliptic Response Designed by the Extracted Pole Technique
José R Montejo-Garai1, Juan E Page1, Gerardo Perez-Palomino1
1Group of Applied Electromagnetics (GEA), Information Processing and Telecommunications Center, Universidad Politécnica de Madrid, 28040 Madrid, Spain.
Abstract:
This paper describes and validates an advanced synthesis design process of Frequency-Selective Surfaces (FSSs) with elliptic band-stop responses. A systematic procedure based on the Generalized Chebyshev Function and the extracted pole technique enables control of the position of the transmission zeros and the attenuation level to obtain an equiripple rejection response. A systematic process is followed to obtain the lumped LC values of the resonator circuits extracted as poles and the impedance inverters. Then, equivalent dipoles and transmission lines are obtained to carry out the electromagnetic design at normal incidence for a linearly polarized field. The impact of the higher-order modes of the periodic structure on the electrical response of the FSS, which can be relevant due to the stringent selected specifications, has been also analyzed. A fourth-order band-stop filter with a 3 GHz bandwidth centered at 30 GHz and its attenuation at 50 dB has been designed considering three different implementations: two filters using a vacuum as a transmission line with different connection lengths and a third one using a dielectric substrate to enable its manufacturing. In order to verify the design procedure using experimental results, the third filter with printed dipoles in the dielectric substrate has been manufactured and measured, thus validating the developed process.
Related Concept Videos
Transfer function and Bode Plots-II
Pole and System Stability
Simple poles are unique roots of the denominator polynomial. Each simple pole corresponds to a distinct solution to the system's characteristic equation, typically resulting in exponential decay terms in the system's...
Frequency-Domain Interpretation of PD Control
The proportional control gain, combined with the...
Bode Plots Construction
Construction of Root Locus
For positive gain values, the root locus exists on the real axis to the left of an odd number of finite open-loop poles or zeros. The root locus starts at the open-loop poles and traces the paths of the closed-loop poles as the gain...
Control System Problem
When forming a closed-loop system, issues can arise if the poles cross into the unstable region, leading to potential...