O-cresol Concentration Online Measurement Based On Near Infrared Spectroscopy Via Partial Least Square Regression
Published on: November 8, 2019
Strategies for multivariate characterization and classification of pulps and papers by near-infrared spectroscopy
Hajar Khaliliyan1, Åsmund Rinnan2, Laura Völkel1
1University of Natural Resources and Life Sciences (BOKU), Institute of Chemistry of Renewable Resources, Konrad-Lorenz-Straße 24, 3430, Tulln, Austria.
Background:
Multivariate calibration by Partial Least Squares (PLS) on near-infrared data has been applied successfully in several industrial sectors, including pulp and paper. The creation of multivariate calibration models relies on a set of well-characterised samples that cover the range of the intended application. However, sample sets that originate from an industrial process often show an uneven distribution of reference values. This can be addressed by curation of the reference data and the methodology for multivariate calibration. It needs to be better understood, how these approaches affect the quality and scope of the final model.
Results:
We describe the effect of log10 transformation of the reference values, regular PLS, robust PLS, the newly introduced bin PLS, and their combinations to select more evenly distributed reference values for the quantification of five pulp characteristics (kappa number, R18, R10, cuen viscosity, and brightness; 200 samples) by near-infrared spectroscopy. The quality of the models was assessed by root mean squared error of prediction, calibration range, and coverage of sample types. The best models yielded uncertainty levels equivalent to that of the reference measurement. The optimal approach depended on the investigated reference value.
Significance:
Robust PLS commonly gives the model with the lowest error, but this usually comes at the cost of a notably reduced calibration range. The other approaches rarely impacted the calibration range. None of them stood out as superior; their performance depended on the calibrated parameter. It is therefore worthwhile to investigate various calibration options to obtain a model that matches the requirements of the application without compromising calibration range and sample coverage.
More Related Videos
10:25Construction of Models for Nondestructive Prediction of Ingredient Contents in Blueberries by Near-infrared Spectroscopy Based on HPLC Measurements
Published on: June 28, 2016
06:54Author Spotlight: Advances in Nanoscale Infrared Spectroscopy to Explore Multiphase Polymeric Systems
Published on: June 23, 2023
Related Concept Videos
Infrared (IR) Spectroscopy: Overview
Different compounds display unique properties due to their...
Applications of IR Spectroscopy: Overview
IR Frequency Region: Fingerprint Region
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
IR Spectrum
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0%...
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview