Automated Hydrophobic Interaction Chromatography Column Selection for Use in Protein Purification
Published on: September 21, 2011
Integrated system for temperature-controlled fast protein liquid chromatography. IV. Continuous 'one-column'
Alexander Brean1, Tim W Overton2, Daniel G Bracewell3
1School of Chemical Engineering, College of Engineering and Physica1, University of Birmingham, Edgbaston, Birmingham B15 2TT, England, UK.
Abstract:
Systematic development of a temperature-controlled isocratic process for one-column low-salt hydrophobic interaction chromatography (HIC) of proteins employing a travelling cooling zone reactor (TCZR) system, is described. Batch binding and confocal scanning microscopy were employed to define process conditions for temperature-reversible binding of bovine serum albumin (BSA) which were validated in pulse-response temperature switching HIC experiments, before transferring to TCZR-HIC. A thin-walled stainless-steel column mounted with a movable assembly of copper blocks and Peltier elements (travelling cooling zone, TCZ) was used for TCZR-HIC. In pulse-response TCZR-HIC, 12 TCZ movements along the column desorbed 86.3% of the applied BSA monomers in 95.3% purity depleted >6-fold in 2-4 mers and nearly 260-fold in higher molecular weight (HMW) species. For continuous TCZR-HIC, the TCZ was moved 49-58 times during uninterrupted loading of BSA feeds at 0.25, 0.5 or 1 mg·mL-1. Each TCZ movement generated a sharp symmetrical elution peak. In the best case, (condition 1: 0.25 mg·mL-1 BSA; >17 mg BSA applied per mL of bed) the height of TCZ elution peaks approached pseudo-steady midway through the loading phase with no rise in baseline UV280 signal between peaks. Peak composition remained constant averaging 94.4% monomer, 5.6% 2-4 mers and <0.05% HMW. Monomers were recovered in quantitative yield depleted >3.1 fold in 2-4 mers and 92-fold in HMW species cf. the feed (63.6% monomers, 21.8% 2-4 mers, 14.6% HMW). However, increasing the BSA concentration to 1 mg·mL-1 (condition 2) or employing a fouled HIC column with 0.5 mg·mL-1 BSA (condition 3) compromised monomer purification performance.
More Related Videos
07:19Author Spotlight: Optimizing Affinity Chromatography for His-Tagged FEN1 Protein
Published on: April 26, 2024
09:34Improved Polymerase Chain Reaction-restriction Fragment Length Polymorphism Genotyping of Toxic Pufferfish by Liquid Chromatography/Mass Spectrometry
Published on: September 20, 2016
Related Concept Videos
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Elution Process
Types Of Column Chromatography
Gel Filtration Chromatography
When the...
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
Size-Exclusion Chromatography
Silica particles offer advantages such as rigidity,...